R240D
Hardware Installation and Maintenance Guide
Com
pone
nt
Issue 03 (2016-01-26)
Applic
No.
able
Check Item
Scope
The devices are installed correctly, securely, without
2
General
damages or paint peeling. Screws are tightened.
Leave at least 20 cm space at the cable outlet and top
(convex) of the AP to facilitate commissioning, maintenance,
and heat dissipation. APs that dissipate heat from the rear
3
General
must be fixed using mounting brackets in wall mounting
scenarios. Ensure that there is a certain space between the
APs and wall to facilitate heat dissipation.
APs with built-in antennas should be installed in open areas
and there should be no obvious obstruction in the coverage
4
General
direction of the main lobe. The main lobe of built-in antennas
faces the top (convex).
The APs and antennas are neatly installed, without affecting
5
General
the overall layout of the environment.
Indoor APs are placed far away from windows and in dry
Indoor
environments with little dust and good ventilation. There
6
AP
should be no inflammable materials in rooms. The indoor
temperature and humidity must be within acceptable ranges.
When being mounted to a ceiling, the APs must be fixed
using the matching mounting brackets. The APs cannot be
Indoor
hung in the air or placed directly on the ceiling. When the
7
AP
APs are mounted to a wall, the bottom of the APs should be
at least 30 mm from the ground. The APs should be installed
in places out of reach of people.
When two or more APs are installed in the same area, they
Outdoor
8
must be installed in the same vertical or horizontal line with
AP
certain spacing greater than 15 mm.
Dustproof, waterproof, and anti-theft measures are taken and
the devices are kept clean. The APs are secured using the
security locks (separately purchased) based on onsite
9
General
situations and customer requirements. If APs are placed in a
network box, ensure that the box is well-ventilated, clean,
and dustless, and the ventilation holes are not blocked.
Indoor APs should be mounted on walls with network ports
downwards to prevent device damages caused by water drops
Indoor
or other liquid. Install the device in a site that is free from
10
AP
leaking or dripping water, heavy dew, and humidity, and take
protective measures to prevent water from flowing into the
equipment along the cable.
Outdoor
When an outdoor AP is installed against a wall or pole, keep
11
AP
the indicator downwards for easy observation.
Use waterproof labels to mark the registration names of APs
12
General
on the AC, as well as their channels and IP addresses. The
lables should be attached to the front of the APs for easy
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.