Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS"...
R240D Hardware Installation and Maintenance Guide About This Document About This Document Intended Audience This document describes hardware features of the R240D and provides basic installation methods. This document is intended for: Network planning engineers Hardware installation engineers ...
Hardware Installation and Maintenance Guide 1 Product Overview Product Overview 1.1 Device Structure Figure 1-1 shows the appearance of the R240D. Figure 1-1 Appearance of the R240D Table 1-1 describes interfaces on the R240D. Table 1-1 Interfaces on the R240D...
Page 9
Figure 1-2 Indicator on the R240D The indicator is located inside the panel, which turns on after the AP is powered on. Indicator colors may vary slightly at different temperature. Table 1-2 Description of the indicator on the R240D Type Color Status Description...
The fault cannot be automatically rectified and must be rectified manually. 1.3 Basic Specifications Table 1-3 Basic specifications of the R240D Item Description Technical specifications Dimensions outside the wall 140mm× 86mm× 25mm Issue 03 (2016-01-26) Huawei Proprietary and Confidential...
If a PoE adapter is required, you need to purchase it separately. 2.4 Determining the Installation Position Figure 2-2 shows dimensions of the R240D. Figure 2-2 Dimensions of the R240D (unit: mm) When determining the device installation position, comply with the following rules: ...
Page 23
R240D Hardware Installation and Maintenance Guide 2 AP Installation Figure 2-3 Interfaces of the R240D Table 2-3 shows cable connections of the R240D. Table 2-3 Cable connections Cable Description Phone cable Connects the uplink phone interface to the traditional PSTN.
Page 28
4. If the device still cannot be powered on, the device itself is faulty. Contact Huawei technical support engineers or Huawei agent and ask them to replace the device. Issue 03 (2016-01-26) Huawei Proprietary and Confidential...
Precautions for Assembly Use dedicated tools or tools delivered by Huawei and follow the methods given here during assembly. Hold terminals of cables instead of pulling the cables themselves when installing or removing cable components.
Page 31
When you strip a power cable, do not damage the conductor of the cable. If the bare crimping terminal is not provided by Huawei, the value of L1 is 1 mm (0.04 in.) to 2 mm (0.08 in.) greater than the value of L.
Page 34
When you strip a power cable, do not damage the conductor of the cable. If the bare crimping terminal is not provided by Huawei, you can adjust the value of L as required. Figure 5-7 Stripping a power cable (JG terminal)
Page 50
5 Appendix Testing the Connection of Assembled Cables Context Huawei provides two types of Ethernet cables: straight-through cables and crossover cables. Straight-through cables are connected in a one-to-one manner. They are used to connect terminals such as a computer or switch to network devices. Table 5-7 lists the connections of core wires in a straight-through cable.
For example, in this document, the adapters of cable connectors have separate interfaces. In the actual situation, the adapters may have interfaces fixed on equipment. Use dedicated tools provided or specified by Huawei and follow the installation procedure described here.
The system may fail to obtain information about non-Huawei-certified optical modules or obtain incorrect information. You are advised to use Huawei-certified optical modules. Obtain the electronic label of the optical module and contact Huawei technical support personnel to confirm whether it is a Huawei-certified optical module.
Page 109
Fiber connectors and optical ports that are not used must be protected with protective caps or plugs. Cleaning must be carried out in strict accordance with Huawei tool specifications. The feeder cables shall not be bent or twisted, with no copper General wire exposed.