Description
5) Requirements:
The control stability (closed-loop PI control) is referred to the rated motor speed and applies
when the SIMOREG converter is warm The following conditions are applicable: -Temperature
changes of ±10 °K
-
Line voltage changes corresponding to +10% /
-
Temperature coefficient of temperature-compensated tacho-generators 0.15‰ per 10 °K
(applies only to analog tacho-generator)
Constant setpoint (14-bit resolution)
-
6) Also refer to Section 3.3 and 9.
7) Also permissible for 2AC 460 (+10% / – 20%).
3.5

Applicable standards

VDE 0106 Part 100
Arrangement of operator control elements in the vicinity of components/parts at hazardous voltage
levels.
VDE 0110 Part 1
Insulation coordination for electrical equipment in low-voltage installations.
Degree of pollution 2 for boards and power section.
Only non-conductive contamination is permissible. Occasional conductivity due to moisture
condensation must, however, be expected.
"Moisture condensation is excluded, as the components are only permitted for humidity class F."
EN60146 T1-1 / VDE 0558 T11
Semiconductor converter
General requirements and line-commutated converters
DIN EN50178 / VDE 0160
Regulations for equipping electrical power systems with electronic equipment.
EN61800-3
Variable-speed drives, part 3, EMC Product Standard including special testing procedures
DIN IEC 60068-2-6 acc. to severity grade 12 (SN29010 Part1)
Mechanical stressing
3.6

Abbreviations

CB
Communications board
PKW
Parameter ID value
PZD
Process data
TB
Technology board
ZSW
Status word