Huawei DBS3900 Installation Manual page 52

Lampsite
Hide thumbs Also See for DBS3900:
Table of Contents

Advertisement

LampSite
Installation Guide
If...
The external power supply ranges from
100 V AC to 240 V AC
The external power supply does not
range from 100 V AC to 240 V AC
Step 3 Power on the RHUB3908. Wait 3 to 5 minutes, check the status of the RUN indicator of the
RHUB3908 after the RHUB3908 runs properly.
If the Status of
the RUN
Indicator...
Steady on
Steady off
On for 1s and off
for 1s
On for 0.125s and
off for 0.125s
----End
Issue 08 (2015-01-15)
It Indicates that...
The power supply is
normal while the board is
faulty.
There is no power input
or the board is faulty.
The devices work
properly.
The board software is
being uploaded.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Then...
Go to
Step
3.
Find out the cause and ensure that the resistance
meets requirement. Then, go to
Then...
Power off the RHUB3908, and power on it
again after rectifying the board fault.
Power off the RHUB3908, and check the
power input again. Rectify the board faulty
and power on the RHUB3908 again if the
power input is normal.
End the operation.
Power off the RHUB3908 if the uploading is
not finished in 5 minutes, and check whether
the configuration file is correct. Power on the
RHUB3908 again after the fault is rectified.
5 Installing an RHUB3908