Temperature
controller
Commun
Series
ication
Connection diagram number
Type
RS-485 connection diagram 17)
*8
RS-485
UM33A
RS-485 connection diagram 19)
UT52A
*3
UT55A
RS-485
*4
UP55A
*5
UM33A
RS-485 connection diagram 10)
For *1 to *6, only the products that meet the following conditions can be connected.
Annotation
*7
Product manufactured by MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED. For details of the product, contact
MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED.
Connection cable
Cable model
Max.
distance
1200m
(4-wire type)
1200m
(2-wire type)
1200m
(2-wire type)
Suffix code
Function
Open network
1 or 2
-
*1
-
1
2
-
Other than 3
1
*2
-
-
-
-
*3
1 or 2
-
2
-
*4
-
-
*5
1
-
*6
1
-
8. CONNECTION TO YOKOGAWA TEMPERATURE CONTROLLER
GOT
Option device
*7
FA-LTBGT2R4CBL05 (0.5m)
*7
FA-LTBGT2R4CBL10 (1m)
*7
FA-LTBGT2R4CBL20 (2m)
*7
FA-LTBGT2R4CBL05 (0.5m)
*7
FA-LTBGT2R4CBL10 (1m)
*7
FA-LTBGT2R4CBL20 (2m)
GT15-RS4-TE
Optional suffix code
Product with two RS-485 communication ports (4-wire type/
Without "/LP"
2-wire type) and without the power supply for 24VDC sensor
Product with the open network port of RS-485
-
communication (4-wire type/2-wire type)
Product with two RS-485 communication ports (4-wire type/
-
2-wire type) (Standard code model)
Product without the additional contact output points (DO)
-
and with the open network port of RS-485 communication
(4-wire type/2-wire type) (Standard code model)
Product with RS-485 communication port (4-wire type/2-wire
With "/CH3"
type) specified in the E3 terminal area option (Detailed code
model)
Product with the RS-485 communication port (4-wire type/2-
With "/C4"
wire type) specified in the E4 terminal area option (Detailed
code model)
Product with two RS-485 communication ports (4-wire type/
With "/LP"
2-wire type) and with the power supply for 24VDC sensor
Product with two RS-485 communication ports (4-wire type/
-
2-wire type) (Standard code model)
Product with the RS-485 communication port (4-wire type/2-
With "/C4"
wire type) specified in the E4 terminal area option (Detailed
code model)
Product with two RS-485 communication ports and without
With "/LP"
the power supply for 24VDC sensor
Product with two RS-485 communication ports (4-wire type)
Without "/LP"
and without the power supply of 24VDC sensor
8.2 System Configuration
Number of connectable
equipment
Model
Up to 31 temperature controllers
for 1 GOT
Remark
8
8 - 11