Ab Slc500 - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

10.4.1 AB SLC500

Device name
B3:0/0 to B3:255/15
Bit (B)
B10:0/0 to B255:255/15
Timer (Timing
T4:0/14(TT) to T4:255/14(TT)
*2
T10:0/14(TT) to T255:255/14(TT)
bit) (T)
Timer (Timing
T4:0/13(DN) to T4:255/13(DN)
*2
T10:0/13(DN) to T255:255/13(DN)
bit) (T)
Counter (Up
C5:0/15(CU) to C5:255/15(CU)
*2
C10:0/15(CU) to C255:255/15(CU)
counter) (C)
Counter
C5:0/14(CD) to C5:255/14(CD)
(Down
C10:0/14(CD) to C255:255/14(CD)
*2
counter) (C)
Counter
C5:0/13(DN) to C5:255/13(DN)
(Completion
C10:0/13(DN) toC255:255/13(DN)
bit) (C)
Integer (N)
*3
Bit (B)
Timer (Set
T4:0.1(PRE) to T4:255.1(PRE)
*1*2
T10:0.1(PRE) to T255:255.1(PRE)
value) (T)
Timer (Current
T4:0.2(ACC) to T4:255.2(ACC)
*1*2
T10:0.2(ACC) to T255:255.2(ACC)
value) (T)
Counter (Set
C5:0.1(PRE) to C5:255.1(PRE)
*1*2
C10:0.1(PRE) to C255:255.1(PRE)
value) (C)
Counter
C5:0.2(ACC) to C5:255.2(ACC)
(Current
C10:0.2(ACC) to C255:255.2(ACC)
*1*2
value) (C)
*1
Integer (N)
*1
Writing to device is not allowed for 32 bit data.
*2
Monitoring or writing is not possible in the continuous device
designation mode.
10 - 22
10. CONNECTION TO ALLEN-BRADLEY PLC
10.4 Device Range that Can Be Set
Setting range
represen
N7:0 to N7:255
N10:0 to N255:255
B3:0 to B3:255
B10:0 to B255:255
N7:0 to N7:255
N10:0 to N255:255
10.4.2 AB MicroLogix Series
Device
No.
Device name
tation
Bit (B)
Timer (Timing
*3
bit) (T)
Timer
(Completion bit)
*3
(T)
Counter (Up
counter) (C)
Decimal
Counter (Down
counter) (C)
Counter
(Completion bit)
*3
(C)
Integer (N)
Bit (B)
Timer (Set
value) (T)
Timer (Current
value) (T)
Counter (Set
value) (C)
Counter
(Current value)
Decimal
*1*3
(C)
Integer (N)
32bit integer
*2
(L)
*1
*2
*3
Setting range
B3:0/0 to B255:255/15
T3:0/14(TT) to T255:255/14(TT)
T3:0/13(DN) to T255:255/13(DN)
C3:0/15(CU) to C255:255/15(CU)
*3
C3:0/14(CD) to C255:255/14(CD)
*3
C3:0/13(DN) to C255:255/13(DN)
N3:0/0 to N255:255/15
B3:0 to B255:255
T3:0.1(PRE) to T255:255.1(PRE)
*1*3
T3:0.2(ACC) to T255:255.2(ACC)
*1*3
C3:0.1(PRE) to C255:255.1(PRE)
*1*3
C3:0.2(ACC) to C255:255.2(ACC)
*1
N3:0 to N255:255
L3:0 to L3:255
L255:0 to L255:255
Writing to device is not allowed for 32 bit data.
Writing to device is not allowed for 16 bit data.
Monitoring or writing is not possible in the continuous device
designation mode.
Device
No.
represen
tation
Decimal
Decimal