134

Ambient Conditions

The following table lists the ACS550 environmental requirements.
Ambient
temperature
humidity
Contamination
(IEC 721-3-3)
Sinusoidal
vibration
(IEC 60068-2-6)
(IEC 68-2-29)
Technical Data
Ambient Environment Requirements
• 0...1000 m (0...3,300 ft)
• 1000...2000 m (3,300...6,600 ft) if
Altitude
P
and I
N
above 1000 m (300 ft above 3,300 ft)
• -15...40 ºC (5...104 ºF)
• Max. 50 ºC (122 ºF) if P
derated to 90%
Relative
< 95% (non-condensing)
• No conductive dust allowed.
• The ACS550 should be installed in
clean air according to enclosure
classification.
levels
• Cooling air must be clean, free from
corrosive materials and free from
electrically conductive dust.
• Chemical gases: Class 3C2
• Solid particles: Class 3S2
• 2...9 Hz 0.3 mm (0.01 in)
• 9...200 Hz 2 m/s
Shock
Not allowed
Not allowed
Free fall
Installation Site
derated 1% every 100 m
2
and I
N
2
2
2
(6.6 ft/s
)
ACS550 User's Manual
Storage and Transportation in the
protective package
-40...70 ºC (-40...158 ºF)
Storage
• No conductive dust allowed.
• chemical gases: Class 1C2
• solid particles: Class 1S2
Transportation
• No conductive dust allowed.
• Chemical gases: Class 2C2
• Solid particles: Class 2S2
Storage
• 2...9 Hz 1.5 mm (0.06 in)
2
• 9...200 Hz 5 m/s
(16.4 ft/s
Transportation
• 2...9 Hz 3.5 mm (0.14 in)
2
• 9...200 Hz 10 m/s
(32.8 ft/s
2
2
max. 100 m/s
(330 ft/s
), 11ms (36 fts)
• 76 cm (30 in), frame size R1
• 61cm (24 in), frame size R2
• 46 cm (18 in), frame size R3
• 31 cm (12 in), frame size R4
• 25 cm (10 in), frame size R5
• 25 cm (10 in), frame size R6
2
)