Panasonic KX-NS1000 Pc Programming Manual page 301

Pure ip-pbx
Hide thumbs Also See for KX-NS1000:
Table of Contents

Advertisement

Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the network.
Maintenance Console Location
9.15 PBX Configuration—[1-1] Configuration—Slot—V-IPEXT32—Port Property
Feature Guide References
5.2.1 IP Proprietary Telephone (IP-PT)
Primary/Secondary
Specifies the designation of the port as a primary port or secondary port.
Note
If an extension has been registered to the port, this setting cannot be changed from "Primary" to
"Secondary". De-register the port to change this setting.
Value Range
Primary, Secondary
Maintenance Console Location
9.15 PBX Configuration—[1-1] Configuration—Slot—V-IPEXT32—Port Property
Feature Guide References
4.2.3.2 Automatic Rerouting to Secondary PBX
Pair Site
Indicates the site where the assigned secondary port is located (reference only).
Note
A value will be displayed here only after the Set Secondary command has been executed (see above).
Value Range
Site number and name
Maintenance Console Location
9.15 PBX Configuration—[1-1] Configuration—Slot—V-IPEXT32—Port Property
Feature Guide References
4.2.3.2 Automatic Rerouting to Secondary PBX
9.15 PBX Configuration—[1-1] Configuration—Slot—V-IPEXT32—Port Property
PC Programming Manual
301

Hide quick links:

Advertisement

Table of Contents
loading