Intensity On Encoder; Releasing Channels; Recording A Cue - Philips 250ML Operation Manual

Lighting control console strand lighting
Table of Contents

Advertisement

250ML Lighting Control Consoles
Operation Guide
Note: Channel levels that are in red have been manually adjusted.
Channel
Channel Level
Figure 28: Channels & Channel Levels
Channels that are in a Red Box with White Text are currently selected. This gives you the ability to apply a new value
without reentering the Channel numbers. So if 1 is currently selected at Full just typing [@] [5] [ENTER] will set the
level to 50%. Any channels in red text are adjusted but not currently selected.

Intensity on Encoder

With selected channels, pressing [SHIFT] + [ENTER] will give you intensity on Encoder A. This shall adjust the
DMX value that is being outputted in either a Relative manner or an Absolute one. It defaults to Relative and the Shift
key will place you so Encoder A works in absolute values. Look to the color screen for DMX values and look to the
monitor for percentage values.

Releasing Channels

[CLR] will remove the last entry onto the command line. [CLR] [CLR] will release any "selected" channels. Those in
a red box with white text. Pressing [CLR] one more time (the third press) will release all adjusted channels.
.
Clear Button
Note: Channel levels that are in red have been manually adjusted.

4. Recording A Cue

Once the channels levels are at the desired levels, the first step is to place the desk into Record Mode.
See "Channels
and Channel Levels" on page 23
for instructions on setting levels.
Figure 29: Recording a Cue Screen
Note: In Record Mode, many commands are limited to recording actions.
24
Recording A Cue