Hitachi IJ UX Service Manual page 182

Hide thumbs Also See for IJ UX:
Table of Contents

Advertisement

(2) Fault locating method for the control system/circulation system
(a) When the pump motor and all the solenoid valves are not operated, the multi-power supply
(24 V system) is abnormal.
(b) If the electrical parts (pump motor, solenoid valves, and pressure sensor) are not operated, i,e.,
any case other than above, make the following checks first. When the criterion is satisfied, the
power supply, EZJ126 board, wiring, or connector is abnormal.
Part
Pump motor
Solenoid valve
Pressure sensor
Check method
(1) Operate the pump
on the "Solenoid
Valve/Pump Test"
screen.
(2) Measure the
voltage at pin
No.5 (wire: red)
(1) Exchange the
solenoid valve
and/or the
connector with
another normal
solenoid valve
and/or connector.
(2) Set the solenoid
value to "Open" on
the "Solenoid
Valve/Pump Test"
screen and check
the sound.
Measure the voltage
at pin No.1
(wire: yellow)
Measure the voltage
at pin No.3 (wire:
blue) when the ink is
jetting.
4-49
Criterion
20 V DC or more
An operation sound shall be
produced.
DC12V±10%
Pressure
Output
[MPa]
voltage [V]
0.1
1.5 to 1.6
0.2
2.1 to 2.2
0.3
2.7 to 2.8