5.10 Mist collector maintenance(applied UX-E only)

1 Remove head cover and heater cover.
2 Unscrew the fixing screw of coupling cover, and then remove the coupling cover.
Mist collector
3 Remove the nut of the mist collector, and then using tweezers, take out O-ring and
the filter from inside. After that, attach a new O-ring P-6EPT and a new PTFE filter
F-20-8.8.
Mist collector
Nut
*Using two 8 mm wrenches, hold
housing by one wrench and remove the nut
by the other wrench.
[Structure of mist collector]
4 Attach the removed nut to mist collector, and then attach all removed parts in the
reverse order of the procedures above.
Housing
Nut
Fixing screw of coupling cover (1 location)
Housing
O-ring P-EPT
PTFE filter F20-8.8
5-16
O-ring P-EPT
PTFE filter
F20-8.8