4.8.4
Motor replacement
Turn off the power supply.
Perform "4.1.3 Approach to the parts on the rear side of the equipment", "(1)Access
method from the front" and open the unit door.
[Caution] Be careful not to catch the tubes.
Remove the connector from the Motor.
Motor
Remove the fixing screws (4 positions) of the motor.
Unit door
Pump unit
Motor
4-25
Motor connector
Fixing screw (4 pcs)