Mitsubishi Electric AJ65BT-64DAI User Manual

Mitsubishi Electric AJ65BT-64DAI User Manual

Digital-analog conversion module

Advertisement

Quick Links

Conversion Module Type
AJ65BT-64DAV/DAI
Thank you for buying the programmable controller MELSEC-A Series
Prior to use, please read both this manual and detailed manual
thoroughly and familiarize yourself with the product.
1996 MITSUBISHI ELECTRIC CORPORATION
Digital-Analog
User's Manual
MODEL
AJ65BT-64DA-U-H-E
MODEL
CODE
IB (NA)-66750-H(1612)MEE
(Hardware)
13J894

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric AJ65BT-64DAI

  • Page 1 User’s Manual (Hardware) Thank you for buying the programmable controller MELSEC-A Series Prior to use, please read both this manual and detailed manual thoroughly and familiarize yourself with the product. MODEL AJ65BT-64DA-U-H-E MODEL 13J894 CODE IB (NA)-66750-H(1612)MEE 1996 MITSUBISHI ELECTRIC CORPORATION...
  • Page 2: Safety Precautions

     SAFETY PRECAUTIONS  (Read these precautions before using this product.) Before using this product, please read this manual and the relevant manuals carefully and pay full attention to safety to handle the product correctly. The precautions given this manual are concerned with this product. Refer to the User’s Manual of the CPU module in use for details on the safety precautions for the programmable controller system.
  • Page 3 CAUTION  Do not bunch the control wires or communication cables with the main circuit or power wires, or install them close to each other. They should be installed 100mm (3.94inch) or more from each other. Not doing so could result in noise that would cause erroneous operation. ...
  • Page 4 [Wiring Precautions] CAUTION  Tighten the terminal screws with the specified torque. If the terminal screws are loose, it could result in short circuits, fire, or erroneous operation. Overtightening can damage the screw and/or module, resulting in drop, short circuit, or malfunction.
  • Page 7: Conditions Of Use For The Product

     CONDITIONS OF USE FOR THE PRODUCT  (1) Mitsubishi programmable controller ("the PRODUCT") shall be used in conditions; i) where any problem, fault or failure occurring in the PRODUCT, if any, shall not lead to any major or serious accident; and ii) where the backup and fail-safe function are systematically or automatically provided outside of the PRODUCT for the case of any problem, fault or failure occurring in the PRODUCT.
  • Page 8: Compliance With Emc And Low Voltage Directives

    This user’s manual describes the specification and handling of AJ65BT-64DAV digital analog-voltage conversion module (abbreviated as AJ65BT-64DAV from here on) and AJ65BT-64DAI digital-analog current conversion module (abbreviated as AJ65BT-64DAI from here on), which is used as the remote device station for the Control &...
  • Page 9: Specifications

    2. Specifications The performance specifications of the AJ65BT-64DAV/DAI is shown below. Specification Item AJ65BT-64DAV AJ65BT-64DAI 16-bit encoded binary (valid bit: 12 bits) Digital input value -2048 to 2047 0 to 4095 Voltage: -10 to 10 VDC Current: 4 to 20mADC...
  • Page 10 3. Name and Setting of Each Part The name of each part in the AJ65BT-64DAV/DAI is described. 3.1 Name of each part BRATE STATION NO. MELSEC J65BT-64DA L RUN CH. OFFSET UP RESET L ERR. GAIN DOWN Name Description Station number The AJ65BT-64DAV/DAI station number is set within setting switch the range 1 to 63...
  • Page 11 : Normal communication Terminal block AJ65BT-64DAV HLD/ HLD/ CH1/ +24V (FG) TEST TEST AJ65BT-64DAI HLD/ HLD/ CH1/ +24V (FG) TEST TEST HOLD/CLEAR setting terminal HOLD is set by shorting between terminals, and CLEAR is set by releasing.
  • Page 12 3.2 Offset/gain setting 4. Handling 4.1 Precautions when handling (1) Do not drop or apply strong shock to the module. Doing so may damage the module. (2) Do not remove the module print board from the case. This may cause breakdowns. (3) Be sure there are no foreign substances such as sawdust or wiring debris inside the module.
  • Page 13 (4) Tighten the screws such as module mounting screws with the following torque: Screw location Tightening torque range Module mounting screw (M4 screw) 0.78 to 1.18N  m Terminal block terminal screw (M3.5 screw) 0.59 to 0.88N  m Terminal block installation screw (M4 screw) 0.78 to 1.18N ...
  • Page 14 0.1 to 0.47F (25V or more voltage resistance parts) specification to the input terminal of the external device. (2) The wiring example to external device for AJ65BT-64DAI is shown below: *1: Use two-core twist shielded line for the wiring. *2: When noise or ripple generates within the external wiring, connect a condenser with 0.1 to 0.47F (25V or more voltage resistance parts) specification to the input terminal...
  • Page 15: External Dimensions Diagram

    7. External Dimensions Diagram Unit: mm(inch) 8. Marking and Information Disclosure for the Restriction on Use of Hazardous Substances in Electrical and Electronic Products Required by the New China RoHS...
  • Page 16 WARRANTY Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi;...