Patch - Yamaha CL1 Reference Manual

Hide thumbs Also See for CL1:
Table of Contents

Advertisement

On-screen buttons and corresponding parameters apply to the following channels:
Button name
Corresponding parameter
WITH MIX SEND
Send level to the MIX bus
WITH MATRIX SEND Send level to MATRIX bus
ALL
All parameters
HA
HA-related settings
HPF
HPF settings
EQ
EQ settings
DYNA 1
Dynamics 1 settings
DYNA 2
Dynamics 2 settings
MIX SEND
Send level to MIX bus
MATRIX SEND
Send level to MATRIX bus
FADER
Fader settings
CH ON
[ON] key settings
On/off setting for STEREO bus
TO ST
assignment, PAN, etc.
On/off setting for MONO bus
MONO
assignment
INPUT PATCH
Input Patching
DIGITAL GAIN
Digital gain settings
INSERT
Insert on/off
INSERT PATCH
Insert patch settings
DIRECT OUT
Direct Out settings
MIX ON
MIX Send On/Off
MATRIX ON
MATRIX Send On/Off
DELAY
Delay settings
NAME
Channel name
OUTPUT PATCH
Output Patching
BAL
BLANCE parameter settings
*1. ST IN channels do not feature these buttons.
0
SAFE PARAMETER SELECT field (DCA)
Enables you to select parameters for a DCA group that will be affected by Recall Safe operations.
If the ALL button is on, all DCA master parameters will be subject to Recall Safe. If LEVEL/ON
is on, the DCA master level and on/off status will be subject to Recall Safe.
STEREO/
Input
MIX
MATRIX
MONO
channel
channel
channel
channel
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
*1
O
O
O
O
*1
O
O
O
O
*1
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
(stereo only)
3.
To select the channel or DCA group that will be affected by Recall Safe operations,
press the corresponding [SEL] key.
The corresponding channel or DCA group will be enclosed by a white frame in the CH RECALL
SAFE field. (However, this white frame does not mean that the Recall Safe setting is now enabled.)
The selected channel or DCA groups 1–8 or 9–16 will be recalled to the SAFE PARAMETER
SELECT field.
NOTE
If the CH RECALL SAFE field's SET BY SEL button is on, Recall Safe will be enabled when you
press the [SEL] key, and the corresponding channel or DCA group will be highlighted in the CH
RECALL SAFE field. You can select parameters as described in step 4 even after turning Recall
Safe on.
4.
If you want to enable Recall Safe for specific parameters of the selected channel or
DCA group, make the following settings in the SAFE PARAMETER SELECT field.
NOTE
• Simply selecting a parameter in step 4 does not enable Recall Safe. To turn Recall Safe on or off,
you must also perform the operation described in step 5 (see
• While the APPLY TO ALL INPUT button (or the APPLY TO ALL OUTPUT button) is on, operations
in the SAFE PARAMETER SELECT field will apply to all input channels (or output channels).
• If an input channel is selected:
Use the buttons in the lower part of the SAFE PARAMETER SELECT field (except for the "ALL"
button) to select the parameters that will be subject to Recall Safe (multiple selections are
allowed). If you want all parameters to be subject to Recall Safe, turn on the ALL button (this is
the default setting).
• If a ST IN channel is selected:
Use the same steps as those for an input channel. (Different buttons will be displayed.)
• If a MIX channel is selected:
Use the buttons in the lower part of the SAFE PARAMETER SELECT field (except for the "ALL"
button) to select the parameters that will be subject to Recall Safe (multiple selections are allowed).
In addition, you can use the WITH MIX SEND button displayed in the lower left of the field to enable
Recall Safe for the on/off status and send level of signals sent from input channels to MIX buses.
If you want all parameters shown in the lower part of the field to be subject to Recall Safe, turn on
the ALL button (this is the default setting).
• If a MATRIX channel is selected:
Use the same steps as those for a MIX channel. (Different types of buttons will be displayed.)
• If a DCA group is selected:
If you press a [SEL] key for a DCA group, all parameters for the DCA groups (selected from DCA
groups 1–8 and DCA groups 9–16) will be displayed simultaneously. For the parameters that will
be subject to Recall Safe, you can select either "ALL" or "LEVEL/ON" (fader position and on/off
status of the [ON] key). Recall Safe will be enabled when you make this selection.
If you want all parameters of the DCA group to be subject to Recall Safe, turn on the ALL button.
Unlike when a channel is selected, Recall Safe will be enabled for that DCA group the moment
you turn on either the LEVEL/ON button or the ALL button.
90
Scene memory
page
91).
Reference Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl3Cl5

Table of Contents