Fader Start - Yamaha CL1 Reference Manual

Hide thumbs Also See for CL1:
Table of Contents

Advertisement

4.
Press the FADER START tab to access the FADER START page.
The following items are displayed.
2
3
5
1
CLEAR ALL button
Press this button to clear all selections.
2
OUTPUT DESTINATION field
• GPI OUT1–GPI OUT5 buttons
Select the GPI OUT port for which you want to make settings.
3
Fader indicator
This indicates the selected fader. Use the [SEL] keys of the console panel to select a fader.
NOTE
In the case of the CL3/CL1, channels that do not exist on those models will not be shown.
1
4
225
4
THRESHOLD field
• UPSTROKE/DOWNSTROKE knobs
These specify the level that will be the threshold for outputting a trigger signal. A trigger signal
will be output when the fader exceeds the UPSTROKE level, or when the fader falls below the
DOWNSTROKE level. If FADER TALLY is selected as the fader mode, UPSTROKE and
DOWNSTROKE specify the level range for which a trigger signal will be output. You can use the
multifunction knobs to operate these parameters.
NOTE
• The THRESHOLD values specified by the UPSTROKE/DOWNSTROKE knobs are common to
all GPI OUT ports. However, you can individually choose the channel (fader) for each GPI OUT
port.
• Only the UPSTROKE value will be valid if MODE is set to FADER START, and only the
DOWNSTROKE value will be valid if MODE is set to FADER STOP. If MODE is set to FADER
TALLY, both the UPSTROKE and DOWNSTROKE values will be valid.
5
MODE field
Here you can select the mode of fader operation that will be the trigger for signal output from the
GPI OUT port.
You can choose from the following fader modes.
• NO ASSIGN
Operating the fader of the selected channel will not cause a signal to be output.

• FADER START

A trigger signal 250 msec long will be output when the fader of the selected channel moves
upward through the specified UPSTROKE level (–138.0 dB to 10.0 dB) from a point below it.
• FADER STOP
A trigger signal 250 msec long will be output when the fader of the selected channel reaches the
specified DOWNSTROKE level (–∞ dB to 9.95 dB).
• FADER TALLY
A trigger signal will be output when the fader of the selected channel moves upward through the
specified UPSTROKE level (–138.0 dB to 10.0 dB) from a point below it. This signal will be held
until the fader reaches the specified DOWNSTROKE level (–∞ dB to 9.95 dB) or until that GPI
OUT port receives a different trigger.
Other functions
Reference Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl3Cl5

Table of Contents