GE D60 Instruction Manual page 446

Line distance relay
Hide thumbs Also See for D60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
F124
ENUMERATION: LIST OF ELEMENTS
bitmask
element
0
Phase Instantaneous Overcurrent 1
1
Phase Instantaneous Overcurrent 2
B
16
Phase Time Overcurrent 1
17
Phase Time Overcurrent 2
24
Phase Directional Overcurrent 1
25
Phase Directional Overcurrent 2
32
Neutral Instantaneous Overcurrent 1
33
Neutral Instantaneous Overcurrent 2
48
Neutral Time Overcurrent 1
49
Neutral Time Overcurrent 2
56
Neutral Directional Overcurrent 1
57
Neutral Directional Overcurrent 2
60
Negative Sequence Directional Overcurrent 1
61
Negative Sequence Directional Overcurrent 2
64
Ground Instantaneous Overcurrent 1
65
Ground Instantaneous Overcurrent 2
80
Ground Time Overcurrent 1
81
Ground Time Overcurrent 2
96
Negative Sequence Instantaneous Overcurrent 1
97
Negative Sequence Instantaneous Overcurrent 2
112
Negative Sequence Time Overcurrent 1
113
Negative Sequence Time Overcurrent 2
120
Negative Sequence Overvoltage
140
Auxiliary Undervoltage 1
144
Phase Undervoltage 1
145
Phase Undervoltage 2
148
Auxiliary Overvoltage 1
152
Phase Overvoltage 1
156
Neutral Overvoltage 1
160
Phase Distance Zone 1
161
Phase Distance Zone 2
162
Phase Distance Zone 3
163
Phase Distance Zone 4
164
Phase Distance Zone 5
168
Line Pickup
172
Ground Distance Zone 1
173
Ground Distance Zone 2
174
Ground Distance Zone 3
175
Ground Distance Zone 4
176
Ground Distance Zone 5
180
Load Enchroachment
190
Power Swing Detect
224
SRC1 VT Fuse Failure
225
SRC2 VT Fuse Failure
226
SRC3 VT Fuse Failure
227
SRC4 VT Fuse Failure
228
SRC5 VT Fuse Failure
229
SRC6 VT Fuse Failure
232
SRC1 50DD (Disturbance Detection)
B-58
bitmask
element
233
SRC2 50DD (Disturbance Detection)
234
SRC3 50DD (Disturbance Detection)
235
SRC4 50DD (Disturbance Detection)
236
SRC5 50DD (Disturbance Detection)
237
SRC6 50DD (Disturbance Detection)
242
Open Pole Detector
272
Breaker 1
273
Breaker 2
280
Breaker Failure 1
281
Breaker Failure 2
280
Breaker Failure 3
281
Breaker Failure 4
288
Breaker Arcing Current 1
289
Breaker Arcing Current 2
290
Breaker Arcing Current 3
291
Breaker Arcing Current 4
292
Breaker Arcing Current 5
293
Breaker Arcing Current 6
294
Breaker 1 Flashover
295
Breaker 2 Flashover
312
Synchrocheck 1
313
Synchrocheck 2
336
Setting Group
337
Reset
360
Trip Output
366
DUTT Pilot Scheme
368
PUTT Pilot Scheme
370
POTT Pilot Scheme
372
Hybrid POTT Pilot Scheme
374
Directional Comparison Blocking Pilot Scheme
376
Autoreclose 1P/3P
385
Selector 1
386
Selector 2
390
Control Pushbutton 1
391
Control Pushbutton 2
392
Control Pushbutton 3
393
Control Pushbutton 4
394
Control Pushbutton 5
395
Control Pushbutton 6
396
Control Pushbutton 7
400
FlexElement™ 1
401
FlexElement™ 2
402
FlexElement™ 3
403
FlexElement™ 4
404
FlexElement™ 5
405
FlexElement™ 6
406
FlexElement™ 7
407
FlexElement™ 8
420
Non-volatile Latch 1
421
Non-volatile Latch 2
422
Non-volatile Latch 3
423
Non-volatile Latch 4
424
Non-volatile Latch 5
D60 Line Distance Relay
APPENDIX B
GE Multilin