GE D60 Instruction Manual page 440

Line distance relay
Hide thumbs Also See for D60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 45 of 48)
ADDR
REGISTER NAME
CAE0
Direct I/O Ch 1 Unreturned Messages Alarm Function
CAE1
Direct I/O Ch 1 Unreturned Messages Alarm Msg Count
CAE2
Direct I/O Ch 1 Unreturned Messages Alarm Threshold
CAE3
Direct I/O Ch 1 Unreturned Messages Alarm Events
CAE4
Reserved (4 items)
B
CAE8
Direct IO Ch 2 Unreturned Messages Alarm Function
CAE9
Direct I/O Ch 2 Unreturned Messages Alarm Msg Count
CAEA
Direct I/O Ch 2 Unreturned Messages Alarm Threshold
CAEB
Direct I/O Channel 2 Unreturned Messages Alarm Events
CAEC
Reserved (4 items)
Remote Devices (Read/Write Setting) (16 modules)
CB00
Remote Device 1 ID
CB08
Remote Device 1 Virtual LAN Identifier
CB09
Remote Device 1 Ethernet APPID
CB0A
...Repeated for Device 2
CB14
...Repeated for Device 3
CB1E
...Repeated for Device 4
CB28
...Repeated for Device 5
CB32
...Repeated for Device 6
CB3C
...Repeated for Device 7
CB46
...Repeated for Device 8
CB50
...Repeated for Device 9
CB5A
...Repeated for Device 10
CB64
...Repeated for Device 11
CB6E
...Repeated for Device 12
CB78
...Repeated for Device 13
CB82
...Repeated for Device 14
CB8C
...Repeated for Device 15
CB96
...Repeated for Device 16
Remote Inputs (Read/Write Setting) (64 modules)
CBA0
Remote Input 1 Device
CBA1
Remote Input 1 Bit Pair
CBA2
Remote Input 1 Default State
CBA3
Remote Input 1 Events
CBA4
Remote Input 1 Name
CBAA
...Repeated for Remote Input 2
CBB4
...Repeated for Remote Input 3
CBBE
...Repeated for Remote Input 4
CBC8
...Repeated for Remote Input 5
CBD2
...Repeated for Remote Input 6
CBDC
...Repeated for Remote Input 7
CBE6
...Repeated for Remote Input 8
CBF0
...Repeated for Remote Input 9
CBFA
...Repeated for Remote Input 10
CC04
...Repeated for Remote Input 11
CC0E
...Repeated for Remote Input 12
CC18
...Repeated for Remote Input 13
CC22
...Repeated for Remote Input 14
CC2C
...Repeated for Remote Input 15
CC36
...Repeated for Remote Input 16
CC40
...Repeated for Remote Input 17
CC4A
...Repeated for Remote Input 18
CC54
...Repeated for Remote Input 19
CC5E
...Repeated for Remote Input 20
B-52
RANGE
UNITS
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
---
0 to 4095
0 to 16383
1 to 16
0 to 64
0 to 3
0 to 1
1 to 64
D60 Line Distance Relay
APPENDIX B
STEP
FORMAT
---
1
F102
0 (Disabled)
---
1
F001
---
1
F001
---
1
F102
0 (Disabled)
---
1
F001
---
1
F102
0 (Disabled)
---
1
F001
---
1
F001
---
1
F102
0 (Disabled)
---
1
F001
---
---
F202
"Remote Device 1"
---
1
F001
---
1
F001
---
1
F001
---
1
F156
---
1
F086
---
1
F102
0 (Disabled)
---
1
F205
DEFAULT
600
10
10
600
10
10
0
0
1
0 (None)
0 (Off)
"Rem Ip 1"
GE Multilin

Advertisement

Table of Contents
loading