Table B–9: MODBUS MEMORY MAP (Sheet 22 of 48)
ADDR
REGISTER NAME
6884
Blocking Scheme 1P Seal In Delay
6885
Blocking Scheme 1P Gnd Directional Overcurrent Fwd
6886
Blocking Scheme 1P Gnd Directional Overcurrent Rev
6887
Blocking Scheme 1P Number of Communication Bits
6888
Blocking Scheme 1P Rx1
6889
Blocking Scheme 1P Rx2
688A
Blocking Scheme 1P Rx3
688B
Blocking Scheme 1P Rx4
688C
Blocking 1P Target
688D
Blocking 1P Event
688E
Reserved (2 items)
Autoreclose 1P 3P (Read/Write Setting)
6890
Autoreclose Mode
6891
Autoreclose Maximum Number of Shots
6892
Autoreclose Block Breaker 1
6893
Autoreclose Close Time Breaker 1
6894
Autoreclose Breaker Manual Close
6895
Autoreclose Function
6896
Autoreclose Block Time Manual Close
6897
Autoreclose 1P Initiate
6898
Autoreclose 3P Initiate
6899
Autoreclose 3P TD Initiate
689A
Autoreclose Multi-Phase Fault
689B
Autoreclose Breaker 1 Pole Open
689C
Autoreclose Breaker 3 Pole Open
689D
Autoreclose 3-Pole Dead Time 1
689E
Autoreclose 3-Pole Dead Time 2
689F
Autoreclose Extend Dead T1
68A0
Autoreclose Dead T1 Extension
68A1
Autoreclose Reset
68A2
Autoreclose Reset Time
68A3
Autoreclose Breaker Closed
68A4
Autoreclose Block
68A5
Autoreclose Pause
68A6
Autoreclose Incomplete Sequence Time
68A7
Autoreclose Block Breaker 2
68A8
Autoreclose Close Time Breaker 2
68A9
Autoreclose Transfer 1 to 2
68AA
Autoreclose Transfer 2 to 1
68AB
Autoreclose Breaker 1 Fail Option
68AC
Autoreclose Breaker 2 Fail Option
68AD
Autoreclose 1P Dead Time
68AE
Autoreclose Breaker Sequence
68AF
Autoreclose Transfer Time
68B0
Autoreclose Event
68B1
Autoreclose 3P Dead Time 3
68B2
Autoreclose 3P Dead Time 4
68B3
Reserved (14 items)
Phase Undervoltage (Read/Write Grouped Setting) (2 modules)
7000
Phase Undervoltage 1 Function
7001
Phase Undervoltage 1 Signal Source
7002
Phase Undervoltage 1 Pickup
7003
Phase Undervoltage 1 Curve
7004
Phase Undervoltage 1 Delay
GE Multilin
RANGE
0 to 65.535
0 to 65535
0 to 65535
0 to 2
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 3
1 to 4
0 to 65535
0 to 655.35
0 to 65535
0 to 1
0 to 655.35
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 655.35
0 to 655.35
0 to 65535
0 to 655.35
0 to 65535
0 to 655.35
0 to 65535
0 to 65535
0 to 65535
0 to 655.35
0 to 65535
0 to 655.35
0 to 1
0 to 1
0 to 1
0 to 1
0 to 655.35
0 to 4
0 to 655.35
0 to 1
0 to 655.35
0 to 655.35
---
0 to 1
0 to 5
0 to 3
0 to 1
0 to 600
D60 Line Distance Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
s
0.001
F001
---
1
F300
---
1
F300
---
1
F198
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F080
---
1
F001
---
1
F300
s
0.01
F001
---
1
F300
---
1
F102
s
0.01
F001
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.01
F001
s
0.01
F001
---
1
F300
s
0.01
F001
---
1
F300
s
0.01
F001
---
1
F300
---
1
F300
---
1
F300
s
0.01
F001
---
1
F300
s
0.01
F001
---
1
F126
---
1
F126
---
1
F081
---
1
F081
s
0.01
F001
---
1
F082
s
0.01
F001
---
1
F102
s
0.01
F001
s
0.01
F001
---
---
F001
---
1
F102
---
1
F167
pu
0.001
F001
---
1
F111
s
0.01
F001
DEFAULT
0
0
0
0 (1)
0
B
0
0
0
0 (Self-reset)
0 (Disabled)
0
0 (1 & 3 Pole)
2
0
10
0
0 (Disabled)
1000
0
0
0
0
0
0
50
120
0
50
0
6000
0
0
0
500
0
10
0 (No)
0 (No)
0 (Continue)
0 (Continue)
100
3 (1 - 2)
400
0 (Disabled)
200
400
0
0 (Disabled)
0 (SRC 1)
1000
0 (Definite Time)
100
B-29