Checking The Cooling System; Checking The Hydraulic Fluid Level - Toro 04384 Operator's Manual

2-wheel-drive traction unit
Hide thumbs Also See for 04384:
Table of Contents

Advertisement

Figure 23
1. Fuel tank cap
2. Remove the fuel tank cap.
3. Fill the tank until the level is 6 to 13 mm (1/4 to 1/2
inch) below the bottom of the filler neck. Do not
overfill. Install the cap.
4. Wipe up any fuel that may have spilled.

Checking the Cooling System

Service Interval: Before each use or daily Clean hourly if
conditions are extremely dusty and dirty.
The capacity of the cooling system is approximately 3.2 L (3.3
US qt). Refer to
Cleaning the Radiator Screen (page
Figure 24
1. Radiator screen
The cooling system is filled with a 50/50 solution of water
and permanent ethylene glycol antifreeze. Check the level of
the coolant at the beginning of each day before starting the
engine.
42).
2. Radiator
CAUTION
If the engine has been running, the pressurized, hot
coolant can escape and cause burns.
• Do not open the radiator cap when the engine
is running.
• Use a rag when opening the radiator cap, and
open the cap slowly to allow steam to escape.
1. Park the machine on a level surface.
2. Check the coolant level
between the lines on the reserve tank when the engine
is cold.
1. Reserve tank
3. If the coolant is low, remove the reserve tank cap and
add a 50/50 mixture of water and permanent ethylene
glycol antifreeze. Do not overfill.
4. Install the reserve tank cap.
Checking the Hydraulic Fluid
Level
Service Interval: Before each use or daily
Recommended Hydraulic Fluid
The machines reservoir is filled at the factory with
approximately 20.8 L (5.5 gallons) of high quality hydraulic
fluid. Check the level of the hydraulic fluid before
the engine is first started and daily thereafter. The
recommended replacement fluid is as follows:
Toro Premium All Season Hydraulic Fluid (Available in 5
gallon pails or 55 gallon drums. See parts catalog or Toro
distributor for part numbers.)
Alternate fluids: If the Toro fluid is not available, other fluids
may be used provided they meet all the following material
properties and industry specifications. We do not recommend
the use of synthetic fluid. Consult with your lubricant
distributor to identify a satisfactory product.
26
(Figure
25). It should be
Figure 25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensmaster 3250-d

Table of Contents