Cleaning the Axle Breathers
Service Interval: Every 300 hours
1. Clean the area around the breathers with a cleaning
solvent
(Figure 75
and
Figure 75
1. Front axle
2. Breather port
Figure 76
1. Rear axle
2. Breather port
2. Remove the breather from the front axle
3. Remove the breather from the rear axle
4. Clean the breathers with a cleaning solvent.
5. Use compressed air to dry the breathers.
Figure
76).
3. Breather fitting
3. Breather fitting
(Figure
(Figure
76).
Important: Wear face protection when using
compressed air.
6. Install the breather in the front axle
7. Install the breather in the rear axle
75).
54
(Figure
75).
(Figure
76).