Toro 25430 Operator's Manual page 41

Traction unit
Hide thumbs Also See for 25430:
Table of Contents

Advertisement

Figure 46
1. Dust valve
2. Air-cleaner cover
Checking the Restricted Air-cleaner
Light
Service Interval: Before each use or daily
1. Start the engine; refer to
2. Check the restricted air-cleaner light on the instrument
cluster
(Figure
47).
Figure 47
1. Instrument cluster
3. Replace the air-cleaner element(s) as follows:
A. Replace the primary air-cleaner element; refer to
Replacing the Primary Element (page
B. Repeat steps
1
C. If the restricted air-cleaner light still comes on,
replace the secondary air-cleaner element; refer to
Replacing the Secondary Element (page
3. Latch
Starting the Engine (page
2. Restricted air-cleaner light
42).
and 2.
42).
Removing the Air-cleaner Cover
1. Remove the left side panel; refer to
Panels (page
2. Pull the latch for the air-cleaner cover outward
46).
3. Rotate the cleaner cover counterclockwise so that the
dust cap is at the 7 o'clock position
1. Latch
2. Air-cleaner cover
4. Pull the air-cleaner cover away from the cleaner housing
25).
to remove the cover
1. Air-cleaner cover
5. Clean the inside of the cover with a clean damp cloth.
41
Removing the Side
36).
(Figure
Figure 48
3. Dust cap
(Figure
49).
Figure 49
2. Air-cleaner housing
(Figure
48).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rt600

Table of Contents