Fujitsu PRIMERGY BX600 User Manual page 82

Hide thumbs Also See for PRIMERGY BX600:
Table of Contents

Advertisement

The Server Blade
I Observe the correct sequence when plugging in the DDR-SDRAM
i
modules. The banks with the highest numbers must be equipped first. If
there are DDR-SDRAM modules with different capacities, put the higher-
capacity modules as near as possible to the chip set.
Example: If you have a 512 MB memory and a 1GB memory, each
consisting of two DDR-SDRAM modules, put the 1 GB modules in bank
2 (sockets 3 and 4) and the 512 MB modules in bank 3 (sockets 5 and 6).
Requirements
– The relevant server blade has been removed (see
02
BX600
82
Removal and Installation Routines
March 2006
page
02-BX600-73)
U41057-J21-Z146-1-76