Sharp AL-2020 Service Manual page 162

Digital multifunctional system
Hide thumbs Also See for AL-2020:
Table of Contents

Advertisement

SW10 No.3–No.5 Inhibited to use
SW10 No.6 ECM byte/frame
Used to set the frame size of error correction mode to be notified to
the remote machine.
Default: 0 (256 [bytes/frame])
SW10 No.7, No.8 Inhibited to use
SW11 No.1–No.8 Inhibited to use
SW12 No.1–No.4 Call time setup in automatic
transmission (T0 timer setup)
Used to set call time in automatic send.
Setting is made by binary input of N into "(5sec x N) + 30sec" in the
increment of 5sec.
Default: 45sec
SW12 No.5 Inhibited to use
SW12 No.6, No.7 CI detection
Used to set the detection frequency of CI signal (call signal).
Default: 0 0 (4 sine wave)
SW12 No.8 Inhibited to use
SW13 No.1, No.2 Inhibited to use
SW13 No.3, No.4 Ringing volume
Used to set the ringing volume when call-in.
Default: 1 0 (Medium)
SW13 No.5, No.6 Speaker volume in DTMF send
Used to set the volume of transmission and DTMF sound from the
speaker when SPEAKER key is pressed.
Default: 1 0 (Medium)
SW13 No.7, No.8 Inhibited to use
SW14 No.1–No.8 Inhibited to use
SW15 No.1 Busy tone detection time (Lower limit)
Used to set the lower limit of busy tone detection time (ON time).
Default: 0 (250ms)
SW15 No.2 Busy tone detection time (Upper limit)
Used to set the upper limit of busy tone detection time (ON time).
Default: 0 (750ms)
SW15 No.3 Busy tone detection time (Lower limit 2)
Used to set the lower limit 2 of busy tone detection time (ON time).
Default: 1 (150ms)
SW15 No.4–No.8 Signal send level
Used to set signal send level from MODEM.
Setting is made in binary input in the increment of 1dBm.
Default: –11dBm
SW16 No.1–No.4 Modem speed (V.33 mode or less)
Used to set send start speed in communication other than V.34
mode.
In an area of poor communication conditions, it is recommended to
set communication speed to a lower level in advance.
Default: 1 0 0 0 (V.17 14.4kbps)
SW16 No.5, No.6 Modem speed in reception fixed
Used to set receive procedure start speed in a remote machine
other than V.34.
In setting of no fixing, the operations are the same as V.17-
14400BPS.
Default: 0 0 (No fixing)
SW16 No.7, No.8 Inhibited to use
SW17 No.1 Inhibited to use
AL-2020/2035/2040/2050/2060 FAX SOFT SWITCH 12 - 24
SW17 No.2 MH fixed (Except for SG3)
Used to set whether coding capacity is fixed to MH or not in commu-
nication other than SG3.
Default: 0 (No)
SW17 No.3 ECM MMR mode (Except for SG3)
Used to set whether MMR coding capacity is allowed or not in com-
munication other than SG3.
Default: 1 (Yes)
SW17 No.4 ECM JBIG mode (Except for SG3)
Used to set whether JBIG coding capacity is allowed or not in com-
munication other than SG3.
Default: 1 (Yes)
SW17 No.5 Inhibited to use
SW17 No.6 MH fixed (in SG3)
Used to set whether coding capacity is fixed to MH or not in SG3
communication.
Default: 0 (No)
SW17 No.7 ECM MMR mode (in SG3)
Used to set whether MMR coding capacity is allowed or not in SG3
communication.
Default: 1 (Yes)
SW17 No.8 ECM JBIG mode (in SG3)
Used to set whether JBIG coding capacity is allowed or not in SG3
communication.
Default: 1 (Yes)
SW18 No.1–No.8 Inhibited to use
SW19 No.1–No.5 Inhibited to use
SW19 No.6 Recording table automatic print
Used to set whether communication report is automatically output-
ted or not when the number of send/receive items which have not
outputted yet on communication report reaches 50.
When set to 1, they are automatically outputted.
When set to 0, they are not outputted even the number of items
reaches 50.
Default: 0 (No)
SW19 No.7, No.8 Inhibited to use
SW20 No.1, No.2 Line sound monitor range
Used to set line sound monitor range when line sound monitor func-
tion is used.
Default: 0 0 (OFF)
SW20 No.3 Line monitor display
Used to set whether the communication speed and the receive level
are displayed on LCD or not.
Default: 0 (No)
SW20 No.4 Inhibited to use
SW20 No.5 Receivable memory capacity
Used to set the remained memory capacity for allowing call-in.
Default: 0 (128Kbyte)
SW20 No.6–No.8 Inhibited to use
SW21 No.1–No.8 Interval between completion of
communication and the next call
Used to set the interval between completion of communication and
the next call.
Setting is made in binary input.
Default: 6sec
SW22 No.1–No.8 Inhibited to use
SW23 No.1–No.8 Inhibited to use

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: