Sharp AL-2020 Service Manual page 132

Digital multifunctional system
Hide thumbs Also See for AL-2020:
Table of Contents

Advertisement

Main
Sub
code
code
L1
00
Content Feeding is not completed within the
specified time after starting feeding. (The
scan head locking switch is locked)
Detail
The white area and the black marking on the
shading plate are used to obtain the
difference in the CCD level values for
judgment of lock. When the difference in the
levels of which and black is small, it is judged
that the black mark could not be scanned by
lock and the trouble code "L1" is displayed.
Cause
The scan head is locked by the lock switch.
Mirror unit abnormality
The scanner wire is disconnected.
The origin detection sensor abnormality
Mirror motor harness abnormality
Check
Check to confirm that the scan head lock
and
switch is released.
remedy
Use SIM 1-1 to check the mirror
reciprocating operations.
When the mirror does not feed.
Check for disconnection of the scanner wire.
Check the harness and the connector
between the mirror motor and the MCU
PWB.
Replace the mirror unit.
Replace the MCU PWB.
When the mirror does feed.
Use SIM 1-2 to check the mirror home
position sensor.
L3
00
Content Scanner return trouble
Detail
When the mirror base is returned for the
specified time (6 sec) in mirror initializing
after turning on the power, the mirror home
position sensor (MHPS) does not turn ON.
Or when the mirror base is returned for the
specified time (about 6 sec) after start of
copy return, the mirror home position sensor
(MHPS) does not turn ON.
Cause
Mirror unit abnormality
Scanner wire disconnection
Origin detection sensor abnormality
Mirror motor harness abnormality
Check
Use SIM 1-1 to check the mirror
and
reciprocating operations.
remedy
When the mirror does not return.
Check for disconnection of the scanner wire.
Check the harness and the connector
between the mirror motor and the MCU
PWB.
Replace the mirror unit.
Replace the MCU PWB.
When the mirror does feed.
Use SIM 1-2 to check the mirror home
position sensor.
L4
01
Content Main motor lock detection
Detail
When the main motor encoder pulse is not
detected for 100 msec.
Cause
Main motor unit abnormality
Improper connection or disconnection the
main motor and the harness.
MCU PWB abnormality
Check
Use SIM 25-01 to check the main motor
and
operations.
remedy
Check connection of the main motor
harness/connector.
Replace the main motor.
Replace the MCU PWB.
Details of trouble
AL-2020/2035/2040/2050/2060 SIMULATION, TROUBLE CODES 10 - 42
Main
Sub
code
code
L4
32
Content Exhaust fan motor lock detection trouble
Detail
The error detection is started after 2 sec
from starting rotation of the exhaust fan
motor.
1) The continuous rotation state of 250ms is
not detected for 1 sec after starting
detection.
2) When the lock sensor (in the exhaust fan)
detects the HIGH level (unstable) after
detection the lock state (stable state).
Cause
Exhaust fan motor connector connection
trouble
Exhaust fan motor trouble
MCU PWB trouble
Check
Exhaust fan motor connector connection
and
check
remedy
Exhaust fan motor replacement
Replace the MCU PWB.
L6
10
Content Polygon motor lock detection
Detail
The lock signal (specified rpm signal) does
not return within a certain time (about 20
sec) from starting the polygon motor
rotation.
Cause
Polygon motor unit abnormality
Improper connection or disconnection of the
polygon motor and the harness.
MCU PWB abnormality
Check
Use SIM 61-1 to check the polygon motor
and
operations.
remedy
Check connection of the polygon motor
harness/connector.
Replace the polygon motor.
Replace the MCU PWB.
U1
03
Content FAX board battery error (AL-2060 only)
Details The SRAM backup battery voltage on FAX
PWB falls.
Cause
The SRAM backup battery voltage on FAX
PWB falls.
Check
Check voltage of the SRAM back up battery.
and
Replace the battery.
remedy
U2
04
Content EEPROM read/write error (Serial
communication error)
Detail
EEPROM access process error
Cause
EEPROM abnormality
Check
Check that the EEPROM is properly set.
and
Use SIM 16 to cancel the trouble.
remedy
Replace the MCU PWB.
11
Content Counter check sum error (EEPROM)
Detail
Check sum error of the counter area in the
EEPROM
Cause
EEPROM abnormality
Check
Check that the EEPROM is properly set.
and
Use SIM 16 to cancel the trouble.
remedy
Replace the MCU PWB.
Details of trouble

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Al-2050Al-2060Al-2035Al-2040

Table of Contents