2) Method using GX Developer
RUN/STOP can be performed by remote RUN/STOP operation from GX
Developer.
For example, this method can be used to STOP the function for sequence
program write in a place where the inverter is out of reach.
GX Developer
Fig 3.22 Timing Chart for RUN/STOP Using GX Developer
(4) Instructions
Note the following points since the built-in PLC function gives priority to STOP.
• The built-in PLC function enters the STOP status when remote STOP is
performed from any of the remote RUN contact, GX Developer, etc.
• To place the built-in PLC function in the RUN status again after it has been put
in the STOP status by remote STOP, all external factors (remote RUN contact,
GX Developer, etc.) for remote STOP must be set to RUN.
REMARKS
What are RUN and STOP statuses?
• RUN status............. Status where a sequence program is repeating operation from step 0 to
• STOP status .......... Status where sequence program operation is at a stop and the outputs
Step 0
Remote STOP
command
Remote RUN
command
RUN/STOP
status
END instruction.
(Y) are all off.
How to RUN/STOP the Built-in PLC Function
from Outside (Remote RUN/STOP)
END
ON
OFF
OFF
STOP
RUN
STOP status
Step 0
END
0
ON
3
91