Siemens SINUMERIK 840D Diagnostics Manual page 686

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
Error code
Error text
Extension 1
Extension 2
Explanation
Remedy
Error code
Error text
Extension 1
Extension 2
Explanation
Remedy
Error code
Error text
Extension 1
Extension 2
Explanation
Remedy
Error code
Error text
Extension 1
Extension 2
Explanation
Remedy
1-686
0031H
Error in STF initialization
0x40 ;Illegal PDU length
0x41 ;Axes differ in terms of PDU length
0x42 ;PDU length is not a word multiple
0x43 ;Axes differ in terms of NC type.
-
The NC has transferred illegal key data for communication via the drive bus. The cause is
probably either faults on the drive bus or a defective control module.
Replace the control module. Check cable connections, perform remedial measures
(check shielding or ground connection).
0032H
Errors in transport that can no longer be handled through the Transp. Abbr.
0x20 ;Job management "defective"
0x21 ;Illegal state in RESET_TRANSPO
0x22 ;Checksum incorrect more than 3 times
0x23 ;Receive PDU too long
0x24 ;State 6XX-Abort illegal
NC drive number
Either unrecoverable errors have been detected when communicating on the drive bus, or
the drive software is no longer consistent.
The cause is either a faulty drive bus interface or a hardware error on the control module.
Check the drive bus cable and cable connections, perform remedial measures (check
shielding or ground connection). Replace the control module.
0033H
Error in the internal data, e.g., error in the element/module lists (incorrect formats, etc.)
0x51 ;Incorrect data format in element list
0x52 ;Incorrect conversion group specified in Refresh
-
The drive software is no longer consistent. The cause is probably a hardware error on the
control module.
Reload drive software. Replace the control module.
0034H
Error in software boot section 1
0 or incorrect address
0x60 ;Illegal SERVO reaction on STF handshake
0x61 ;Error during RAM check
0x62 ;Transport checksum does not correspond to that of the SERVO.
Errors were detected on loading the drive software. The cause is either faults during the
transfer via the drive bus or a defective control module.
Check the drive bus cable and cable connections, perform remedial measures (check
shielding or ground connection), replace control module.
 Siemens AG, 2004. All rights reserved