Siemens SINUMERIK 840D Diagnostics Manual page 167

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Remedy:
Program Continuation:
12590
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12600
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12610
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
Modify part program: Replace the on-line variable by an arithmetic variable.
Clear alarm with the RESET key. Restart part program.
Channel %1 block %2 global user data cannot be created
%1 = Channel number
%2 = Block number, label
The number of global user data blocks is defined in machine data
$MC_NUM_GUD_MODULES.
Here, _N_SGUD_DEF corresponds to block 1, _N_MGUD_DEF corresponds to block 2,
_N_UGUD_DEF corresponds to block 3, _N_GUD4_DEF corresponds to block 4 etc.
In the directory _N_DEF_DIR there is a file with definitions for global user data, the block
number of which is greater than the number of blocks given in the MD.
The alarm may, however, also be caused by value zero in one of MD
$MN_MM_NUM_GUD_NAMES_NCK, $MN_MM_NUM_GUD_NAMES_CHAN and by
the definition of a variable with NCK or CHAN in one of the GUD definition files.
- Correction block
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Increase machine data
18118 MM_NUM_GUD_MODULES.
Or, if it already has the correct value, check whether 18120
$MN_MM_NUM_GUD_NAMES_NCK (if a variable has been defined with attribute NCK)
or 18130 $MN_MM_NUM_GUD_NAMES_CHAN (if a variable has been defined with
attribute CHAN) is not zero.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 invalid line checksum
%1 = Channel number
%2 = Block number
On processing an INI file or when executing a TEA file, an invalid line checksum has been
detected.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Correct INI file or correct MD and create new INI file (via "upload").
Switch control OFF - ON.
Channel %1 block %2 accessing single character with call-by-reference parameter
not possible %3
%1 = Channel number
%2 = Block number, label
%3 = Source string
An attempt has been made to use a single character access for a call-by-reference
parameter.
- Correction block
- Interface signals are set.
- Alarm display.
Temporarily store single characters in user-defined CHAR variable and transfer this.
Clear alarm with NC START or RESET key and continue the program.
1 Alarms
1-167

Advertisement

Table of Contents
loading