Siemens SINUMERIK 840D Diagnostics Manual page 415

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Reactions:
Remedy:
Program Continuation:
28031
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
28032
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
28033
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Acknowledge the alarm on the NCU.
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Serious alarm on NCU %1 not yet acknowledged, axes still in follow-up mode
%1 = NCU number
A serious alarm was not yet acknowledged on another NCU. Consequently, all the axes
continue to trail.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Acknowledge the alarm on the NCU.
Alarm display showing cause of alarm disappears. No further operator action necessary.
Emergency stop activated on NCU %1, axes in follow-up mode
%1 = NCU number
The emergency stop request is active at the PLC-NCK interface on one NCU of the NCU
network. Consequently, all axes are trailing.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy the cause of the emergency stop on the NCU and acknowledge the emergency
stop via the PLC-NCK interface.
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Emergency stop on NCU %1, axes still in follow-up mode
%1 = NCU number
The emergency stop request is active at the PLC-NCK interface on one NCU of the NCU
network. Consequently, all axes are trailing.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy the cause of the emergency stop on the NCU and acknowledge the emergency
stop via the PLC-NCK interface.
Alarm display showing cause of alarm disappears. No further operator action necessary.
1 Alarms
1-415

Advertisement

Table of Contents
loading

Table of Contents