Siemens SINUMERIK 840D Diagnostics Manual page 510

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

1 Alarms
111007
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
111008
Definitions:
Reactions:
Remedy:
Program Continuation:
111009
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
111010
Definitions:
Reactions:
Remedy:
Program Continuation:
111100
Definitions:
Reactions:
Remedy:
Program Continuation:
111105
Definitions:
Reactions:
1-510
Error in line %1 %2
%1 = Line number
%2 = Error description
--
- NC Start disable in this channel.
- Alarm display.
Eliminate the corresponding error.
Internal
Spindle not synchronized
Spindle not synchronized.
- Alarm display.
Let the spindle run at least one revolution (M3, M4).
Internal
Load new tool: T%1
%1 = Tool number
Tool change program requests a new tool.
- Alarm display.
- NC Stop on alarm.
Load new tool.
Internal
Teach-in interruption: Log overflow
The Teach-in procedure was interrupted. Teach-in file is closed.
- Alarm display.
In the machine data 9606: $MM_CTM_SIMULATION_TIME_NEW_POS the value of the
update rate is to be increased by 100 to 200 ms.
Internal
Wrong position programmed for the spindle
A position beyond the range of 0 -359.999 has been programmed for a modulo axis.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Program a position in the 0 - 359.999 range.
Clear alarm with the RESET key. Restart part program
No measuring system available
SPCON, SPOS or SPOSA has been programmed.
These functions require at least one measuring system. According to MD: NUM_ENCS
the machine axis/spindle has no measuring system.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04

Advertisement

Table of Contents
loading

Table of Contents