From System Setup, you may access Power Mode Setup, CS Setup, User Setup, Time & Date, and
Advanced Setup.

CS Setup

You may access ECP Address, Options, Screen Security, Device Events, Code Authority and
Panel Configuration from the CS Setup screen.
From the "Home" screen, press the Setup and System Setup icon and perform the following:
ICON
1. From the System Setup screen, press
the CS Setup icon.
2. Enter your Authorized Code, if required.
3. Press the ECP Address icon.
ECP/RIS Automation Address
After enabling addresses in the control panel using an alpha-keypad, power-up each keypad one at a
time, and set its address to one of the addresses you enabled in the control panel. Otherwise, access the
Central Station screen then follow this procedure to change the address on the unit.
To change the address, perform the following:
ICON
1. Press the ECP Address icon.
1
2. Select the ECP address for this keypad
2
3
using the Up/Dn arrows.
3. The available ECP addresses are:
1-2, 5-6
for residential controls
1-2, 3-30
for commercial controls under Rev.
10 supports 3 AUIs. *See
Important Note below.
1-30
for commercial controls Rev. 10
and higher supports 6 AUIs.
*IMPORTANT: If multiple keypads are being used,
they must be set to addresses 1, 2, and X (where X
equals any address from 3 through 30). Only one AUI
type device may be assigned to an address from 3
through 30 on commercial control panels.
NOTE: If using remote services, one of the touch-screen device (AUI) addresses is used by the control
panel. Refer to control panel instructions for specific configuration.

System Setup

ACTION
Selection
ACTION
16
NOTES
If the top of the screen is displaying "ECP Error", the
ECP address in the keypad is not valid for the panel
that it is connected to. In this case, to change the
ECP Address, enter the default code of "4140" to
advance to the next screen.
Note: Default code "4140" is the Tuxedo Touch
default installer code before connecting to a control
panel. Once connected to a control panel, use that
panel's installer code.
NOTES
When the keypad cannot communicate with the
alarm panel, the message "ECP Error" is
displayed, check the following:
Verify that the AUI type device is enabled in
the control panel, and that the ECP address in
the keypad matches the address enabled in the
control panel. Use a different address for each
device.
• If powering the keypad from a power supply,
make sure you have a common ground installed
(wiring between Power Supply "gnd" and panel
"Aux. power neg").
NOTE: When the ECP address is changed, and
Apply is selected, the keypad resets.
The keypad should not be assigned as a Master
Console. If the keypad is assigned as a Master
Console, partitions must be controlled from the
Partition screen or using the Console Emulation
Mode.