7. IN / ON LINE

7-1. C-In line (ARCNET)

1)
C-In line connection diagram
The maximum C-In line cable length and the maximum connection unit will be varied by the in-line
communication speed as shown below list.
[C-In line cable wiring]
Note: When the cluster has more than 8 QT-2000 terminals,
all printer should be local printer.
When the cluster has less than or equal to 8 QT-2000
terminals, remote printer is allowable.
QT2000-1
R/J
C-In line communication speed
(Baud rate)
1.25 M bps
625 K bps
312.5 K bps
156.25 K bps
Note : This C-In line system needs a I/O-PB-12 in the PC.
QT2000-2
QT2000-3
R/J
Maximum
connection unit
8
12
20
32
— 39 —
Install the I/O-PB-12 in
the PC.
PC
In-line
QT2000-4
R/J
R/J
Maximum
cable length A ( m )
86
200
430
890
A
Total Length :
QT2000-32