Note: First f/w upgrade check on system start will be performed
after a random delay of 0-30s
Interval
When Method is set to Periodically, this is the number of seconds
between each checking of f/w upgrade check from FirmwareURL. If
value is 0, device checks once only on system start (i.e., equivalent
to setting Method to System Start)
The time during the day at which to execute ConfigURL is the
TimeofDate
Method is set to "Time Of Day". It must be specified in the format:
hh:mm
RandomDelayRange
FirmwareURL
URL of firmware package. URL must include scheme. Supported
schemes are http:// and tftp://
DnsLookupType
Choices are:
-
-
-
DnsSrvPrefix
Choices are:
-
-
-
Username
Optional Username for authentication if URL scheme is http://
Password
Optional Password for authentication if URL scheme is http://
(X_DeviceManagement.ITSPProvisioning.)
ITSP Provisioning
(X_DeviceManagement.Provisioning.)
OBiTALK Provisioning
Method
Current operational method of Provisioning. Available choices are:
-
-
system start
-
and then periodically at the interval specified in the Interval
parameter
-
the time specified in the TimeofDay parameter
Note: First download on system start will be performed after a
random delay of 30 – 90s. If there is a firmware update scheduled
at the beginning. Or a random delay of 10- 70s..
Interval
When Method is set to Periodically, this is the number of seconds
between download from ConfigURL. If value is 0, device downloads
once only on system start (i.e., equivalent to setting Method to
System Start)
The time during the day at which to execute ConfigURL is the
TimeofDate
Method is set to "Time Of Day". It must be specified in the format:
+
[
rr] where:
hh
-
: 0 – 23
mm
-
: 0 – 59
+rr
-
: (optional) maximum range of random delay in
minutes from 0 – 360. If not specifieid, the default is
rr
30 minutes. Setting
=
delay.
A Record Only
SRV Record Only
Try Both
No Prefix
With Prefix
Try Both
and
Disabled = Do not download from ConfigURL
System Start = Download from ConfigURL just once on
Periodically = Download from ConfigURL on system start,
Time Of Day = Download from ConfigURL once a day at
Copyright 2010-2015 Obihai Technology, Inc.
0
will remove the random
0
00:00+30
30
A Record Only
No Prefix
System Start
0
00:00+30
178