Honeywell LYNX Touch Series Installation And Setup Manual page 42

Hide thumbs Also See for LYNX Touch Series:
Table of Contents

Advertisement

LYNX Touch Installation and Setup Guide
Programming the Control
SCREEN
Quick Arm
Yes
Quick Exit
Yes
Restart Exit Time
Yes
Force Bypass
No
Exit Warning
Yes
Auto Stay Arming
Yes
Lack of Usage Notify
Disabled
Power-Up In Previous
Yes
Display Alarm Cancel
Yes
Display Exit Time
Yes
Cross Zone Delay
None
Cross Zone 1
Disabled
Cross Zone 2
Disabled
Select "Quick Arm". The System toggles between Yes and No.
Select "Quick Exit". The System toggles between Yes and No.
Select "Restart Exit Time". The System toggles between Yes and No.
SIA: The LYNX Touch default is "Yes".
Select "Force Bypass". The System toggles between Yes and No.
UL installations: must be NO (no forced bypass)
Select "Exit Warning". The System toggles between Yes and No.
SIA: The LYNX Touch default is "Yes" and is not selectable.
Select "Auto Stay Arming". The System toggles between Yes and No.
SIA: The LYNX Touch default is "Yes".
Select "Lack of Usage Notify". The System scrolls between the following options:
Disabled
1 Day
7 Days
27 Days
90 Days
180 Days
365 Days
Select "Power-Up In Previous". The System toggles between Yes and No.
Note: If the previous state was Armed Away or Stay, the system will not respond to sensor changes for
1 minute. This allows time for sensors such as PIRs to stabilize.
UL installations: must be Yes (power up in previous state)
SIA: The LYNX Touch default is "Yes" and is not selectable.
Select "Display Alarm Cancel". The System toggles between Yes and No.
Select "Display Exit Time". The System toggles between Yes and No.
Select "Cross Zone Delay". The System toggles between the following:
None
30 Seconds
1 Minute
90 Seconds
2 Minutes
3 Minutes
4 Minutes
Note: Cross zoning can not be used in conjunction with APL.
Select "Cross Zone 1". The System toggles between the following:
Disabled
Note: If Cross Zone Delay is enabled the system will display the zones that are programmed with the
following Zone Types: Day/Night, Interior Follower and perimeter.
Select "Cross Zone 2". The System toggles between the following:
Disabled
Note: If Cross Zone Delay is enabled the system will display the zones that are programmed with the
following Zone Types: Day/Night, Interior Follower and perimeter.
ACTION
- 42 -

Hide quick links:

Advertisement

Table of Contents
loading