LYNX Touch Series Control
Quick Installation Guide
This Quick Installation Guide can help you install the rechargeable LYNX Touch Series Control quickly and easily by providing the basic steps for installation using the built-in defaults.
FOR DOCUMENTATION AND ONLINE SUPPORT:
Guide P/N 800-10614 or higher.) A copy of the Installation and setup Guide may also be requested from Honeywell.
1. Install the Control
INSTALL
SCREW
IN CASE
CASE
TIE WRAP
TAMPER
TAMPER
POINTS (3)
DETAIL A
BATTERY
CABLE CHANNEL
WIRE ROUTING
CLIPS (3)
MOUNTING
HOLES (4)
ILP5 RECEPTACLE
KNOCKOUT
MOUNTING
HOOKS
(HINGES)
TELEPHONE
CONNECTIONS
GSMVLP5-4G/ILP5
RECEPTACLE
EDGE
CONNECTOR
FRONT
CASE
TAMPER
SWITCH
TIE WRAP
POINTS (2)
LOCKING TABS
1. Release the front case from the rear case by depressing the two
locking tabs at the top of the unit with the blade of a medium size
screwdriver.
2. Separate the front and back case assemblies by rotating the front
case so that it is perpendicular to the rear case and unsnapping
(releasing) the two hooks (hinges) from the back case.
3. Feed the wiring through the appropriate openings in the back
case. Use tie wraps to secure the wiring to the built-in wire loops
as needed.
4. Mount the back case to a sturdy wall and secure with the provided
screws.
5. If required, install an additional mounting screw in the case
tamper (see Detail A).
6. Attach the front and back cases by connecting the hooks on the
front case to the attachments on back case. Once attached, the
hooks will support the front case and allow you to make the wiring
connections.
7. After all of the wiring connections have been made, snap the front
case and back case closed and ensure that the locking tabs
secure the case.
Ê800-110599Š
800-11059 2/12 Rev. A
http://www.security.honeywell.com/hsc/resources/MyWebTech
2. Make Wiring Connections
WARNING
UL NOTE
TO PREVENT
THE MINIMUM WIRE SIZE USED FOR TELEPHONE
RISK OF SHOCK,
INSTALLATIONS MUST BE #26 GAGE
DISCONNECT
TELEPHONE LINE
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
AT TELECOM
JACK BEFORE
SERVICING
THIS UNIT
INCOMING
BACK
INCOMING
PHONE
CASE
PHONE LINE
LINE
PREMISES
TELEPHONE
EARTH
GROUND
ILP5
SPACER
TIP RING TIP
RING
POWER
SUPPLY
RECEPTACLE
ROTATE
FRONT CASE
UPWARD
TO RELEASE
HOOKS
TELCO
JACK
PHONE
TERMINAL
STRIP
GSMVLP5-4G/ILP5
EDGE CONNECTOR
RECEPTACLE
EDGE
(L5100-ZWAVE)
CONNECTOR
WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM
Note: For the complete Summary of Connections, refer to the LYNX
5100-100-078-V0
Touch Series Installation and Setup Guide P/N 800-10614 or
higher.
1. Make earth ground connections to EGND terminal.
2. Connect the incoming phone line to either the 8-position jack or
the TIP and RING terminals.
3. Connect the handset phone lines to the H/S T (TIP) and H/S R
(RING) terminals.
Note: For full line seize operation, refer to the LYNX Touch Series
Installation and Setup Guide.
4 Connect the sensors/contacts to the HWZ1 (+) and GND (-)
terminals.
5. If used, install the GSMVLP5-4G or ILP5 communications module
Refer to the Install the Communications Module section or to the
Installation Guide for the Communications Module (P/N 800-
01115 or higher).
6. Connect wires from the 300-04705/300-04605 OR 300-04063
(Canada) Power Supply to GND (-) and +9VDC (+) terminals OR
plug the Power Supply connector into the receptacle on the LYNX
Touch.
(see LYNX Touch Series Installation and Setup
3. Install the Communications Module
OBSERVE POLARITY WHEN
ETHERNET CABLE
CONNECTING THE POWER
TO ILP5
SUPPLY TO THE TERMINAL STRIP.
RJ45 RECEPTACLE
NOTE
USE ONLY THE
LYNX TOUCH
300-04705/300-04605
OR 300-04063
ALTERNATE INSTALLATION
POWER SUPPLY
PROVIDED
HARD
ILP5
SPACER
WIRED
300-04705 or 300-04605
ZONE
(300-04063 CANADA)
RJ45
POWER SUPPLY
2K
RECEPTACLE
9V, 2.7A
CONNECTOR
OHM
BOARD
EOLR
ROTATED
TIE
180
WRAP
(1)
ILP5
POWER SUPPLY
CONNECTOR
SIM CARD
CONNECTOR BOARD
SCREW
GSMVLP5-4G
(3)
ZONES
POWER
EDGE CONNECTOR
ROTATED
(L5100-WiFi)
180
RECEPTACLE
CONNECTOR BOARD
5100-100-076-V0
LYNX TOUCH
Ensure that SIM card and the connector board are securely
installed in the communications module before installing it
in the LYNX Touch.
1. If you are installing the ILP5 module, use a wire cutter or knife to cut
the plastic tabs that secure the ILP5 spacer to the back case of the
LYNX Touch. If you are installing the GSMVLP5-4G module,
proceed to step 3.
2. Remove the ILP5 receptacle knockout from the left side of the
LYNX Touch back case
3 Install the Communications Module into the front case. Ensure that
the connector board is properly seated into the receptacle on the
control.
4 Secure the module with the three provided screws. If you are
installing the ILP5 module, proceed to step 5. If you are installing
the GSMVLP5-4G module, proceed to step 8
5. Insert the ILP5 receptacle and spacer into the slot on the back
case.
6. Secure the communications cable to the tie wrap point on the ILP5
with the provided tie wrap.
7. Connect the Ethernet cable to the RJ45 receptacle.
8. Enable the module, configure alarm reporting and module
supervision and register the device. Refer to the "Communications
Diagnostics" section of the LYNX Touch Installation Guide (P/N
800-10614 or higher).
For the latest warranty information, please go to:
4. Make Battery Connections
SCREW
NOTE:
SIM CARD INSTALLED
IN GSMVLP5 ONLY
RETAINER
REMOVE
REMOVE
ILP5
ILP5
LYNXRCHKIT-SHA
KNOCKOUT
SPACER
(P/N 300-03866)
TIE
WRAP
POINT
5100-100-077-V0
1. Remove screw securing the battery retainer.
2. Remove the battery retainer.
3. Insert battery pack into back case.
4. Install battery retainer.
5. Install screw to secure the battery retainer.
6. Connect battery connector to receptacle on PC board.
7. After all wiring connections have been made, snap the front case
to the back case so it is held by the locking tabs.
8. Plug the Power Supply into a 24-hour, 110VAC unswitched outlet.
Note: Rechargeable batteries may take up to 48-hours to fully
charge. "Battery Low" message should clear within four hours,
or by entering Test Mode.
Battery
Part Number
LYNXRCHKIT-SC
(300-03864-1)
LYNXRCHKIT-SHA
(300-03866)
WARRANTY INFORMATION
www.honeywell.com/security/hsc/resources/wa
SCREW
RETAINER
LYNXRCHKIT-SC
(P/N 300-03864-1)
OR
5000-100-018-V1
Battery Standby
Low Battery Notification
Time (Minimum)
Approx. 1-hour before
4-hours
battery depletion
At least 1-hour before
24-hours
battery depletion
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2012 Honeywell International Inc.
www.honeywell.com/security

Advertisement

loading

Summary of Contents for Honeywell LYNX Touch Series

  • Page 1 LYNX Touch Series Control Quick Installation Guide This Quick Installation Guide can help you install the rechargeable LYNX Touch Series Control quickly and easily by providing the basic steps for installation using the built-in defaults. WARRANTY INFORMATION FOR DOCUMENTATION AND ONLINE SUPPORT: (see LYNX Touch Series Installation and Setup http://www.security.honeywell.com/hsc/resources/MyWebTech...
  • Page 2 LYNX Touch Installation and Setup Guide P/N 800-10614 or Report All 4. Enter a new 4-digit User Code. Note: Refer to the Lynx Touch Series User Guide P/N 800-10615 or higher for additional information) Report Alarms 5. Select “Done”.