Honeywell LYNX Touch Series Installation And Setup Manual page 38

Hide thumbs Also See for LYNX Touch Series:
Table of Contents

Advertisement

LYNX Touch Installation and Setup Guide
Programming the Control
SCREEN
Number of Reports
2 Reports
Alarm Report Delay
30 Sec.
First Report Offset
6 Hrs
Report Frequency
Never
Downloader
Phone Answer
Yes
Modem Speed
Slow
Ans. Machine Defeat
Yes
Callback Number
Ring Counter
2
Flexible Callback
No
Number
1
Select "Number of Reports"
LYNX Touch
The system scrolls between the following options:
1, 2, 3, 4, 5 and 6 Reports
LYNX Touch (L5100CN) Canada
The system toggles between "Unlimited" and "10 Reports".
Select "Alarm Report Delays". The System scrolls between the following options:
15 Sec.
30 Sec.
45 Sec.
No delay
SIA The Alarm Report Delay (burglary abort window) must be set to a minimum of 15
seconds. The sum of the burglary abort window and the entry delays should not
exceed 1 minute.
Note: The LYNX Touch control validates the data entered in this field. If the selection is not
valid the control will emit a single long beep indicating that the selection has been rejected.
The control replaces the selection with the default value "30 Sec".
Select "First Report Offset" for the Test Report. The System scrolls between the following
options:
6 Hrs
12 Hrs
18 Hrs
24 Hrs
Select "Report Frequency" for the Test Report. The System scrolls between the following
options:
Never
Every Day
Every 7 Days
Every 30 Days
Select "Downloader". The System displays the following options:
Phone Answer
Ans.Machine Defeat
Ring Counter
Select "Phone Answer", the system toggles between "Yes" and "No".
(Future Use)
Select "Ans. Machine Defeat", the system toggles between "Yes" and "No".
Select "Callback Number" and enter callback number on the displayed keypad.
This option only appears if Answering Machine defeat is set to "No". Enter ring counter (1 –
14 rings) on the displayed keypad.
Select "Flexible Callback", the system toggles between "Yes" and "No".
This option only appears if "Flexible Callback" is set to "Yes". The system scrolls between
options 1, 2 and 3.
ACTION
Modem Speed
Callback Number
Flexible Callback
Number
- 38 -