30
Advanced RF communication check
!
To save power the battery
devices only communicate
with the evohome
Controller every four minutes
therefore the system may not
respond immediately to a
manual change.
Step 4: System test
To check the RF signal strength between the
wireless devices and the evohome Controller go
to RF COMMS CHECK in the evohome Controller
Installer Menu and test each wireless device.
On the evohome Controller press and
1
hold 'Settings' for 3 seconds
Press the green tick
2
Press RF COMMS CHECK
3
Choose the devices you want to test
4
Mains Powered Wireless Devices
Mains powered devices do not need to be put into
test mode and will automatically respond to the test
message sent from the evohome Controller:
Wireless Relay Box (BDR91)
• The Relay Box will flash the green LED from 1 flash (poor)
to 5 flashes (excellent) – no flashing means the Relay Box
has not received a test signal from the evohome Controller
Remote Access Gateway (RFG100)
• The Gateway will flash the green LED from 1 flash (poor) to
5 flashes (excellent) – no flashing means the Gateway has
not received a test signal from the evohome Controller
Underfloor Heating Controller (HCE80/HCC80)
• The Underfloor Heating Controller will flash the
green LED for the zone you are testing from 1 flash
(poor) to 5 flashes (excellent) – no flashing means
the Underfloor Heating Controller has not received
a test signal from the evohome Controller