HONEYWELL 7000 SOLID STATE ALARM SYSTEM
Location
Locate the control panel enclosure in an area that is dry and
not subject to temperature extremes. Prolonged exposure to
temperatures below 32°F (0°C) or above 120°F (50°C) can
adversely affect the battery and some system circuits.
The location selected should be well inside the secured area
and accessible for testing and reprogramming. Allow for
routing wire runs. Locate the control panel enclosure and any
accessory equipment, such as the PEM or RFEM in:
a. Interior closet.
b. Interior wall in an untravelled area.
NOTE: If a cement, brick or cinderblock wall is to
be used as a mounting location, use an
appropriately sized piece of 3/4 in. (19 mm)
plywood attached to the wall with wall
anchors as a base for the system.
CIRCUIT
BOARD
69-1192—1
SUPPLIED (4)
Fig. 2. Mounting the control panel enclosure on drywall.
Mounting (Fig. 2 and 3)
Determine what equipment will be mounted on the wall with
the control panel box, approximate location of each device,
and probable wiring runs. This can be a rough sketch, with
approximate dimensions of the devices (see Specifications).
Based on this information, cut the 3/4 in. (19 mm) plywood, if
necessary, to the appropriate dimensions and mount the
plywood on the selected wall using wall anchors or expansion
plugs.
IMPORTANT
For RF installations, mount the RF Receiver at least
25 feet away from any other sources of RF
interference, such as garage door opener receivers.
Avoid mirrors and reflecting surfaces such as metal
heating and cooling ducts. If insufficient RF strength
is noted, move the receiver.
DRYWALL
ANCHORS
(NOT SUPPLIED)
CONTROL
BOX
4
DRYWALL
M10908