Honeywell 7000 Solid State Alarm System

APPLICATION

The Honeywell 7000 is a solid state fire/burglary and home
health care alarm system designed to protect a wide range of
private residences. This UL-listed system is easily
expandable and can be customized to meet the demanding
needs of homeowners.
® U.S. Registered Trademark
Copyright © 1998 Honeywell Inc. • All Rights Reserved

FEATURES

• Can display up to 96 points of protection.
• Eight hardwire zones built into the control panel.
• Optional RF and hardwired expansion on Hbus.
• Supports keypads with custom text displays.
• Mode-based operation for simple error-free control.
• Date and time stamped event log.
• Up to 24 fully programmable outputs.
Application .......................................................................... 1
Features .............................................................................. 1
Specifications ...................................................................... 2
Ordering Information ........................................................... 2
Installation ........................................................................... 3
Programming ....................................................................... 19
Operation ............................................................................ 21
Checkout ............................................................................. 24
Troubleshooting .................................................................. 25
Regulatory Agency Statements ........................................... 26
PRODUCT DATA
Contents
69-1192-1

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell 7000

  • Page 1: Table Of Contents

    PRODUCT DATA APPLICATION FEATURES The Honeywell 7000 is a solid state fire/burglary and home • Can display up to 96 points of protection. health care alarm system designed to protect a wide range of private residences. This UL-listed system is easily •...
  • Page 2: Specifications

    Honeywell, 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
  • Page 3: Installation

    HORN/BELL SMOKE DETECTOR BATTERY HARDWIRE LOOPS CONTROL PANEL HBUS MODES FIRE OPTIONS POLICE SPECIAL CANCEL RF TRANSMITTERS KEYPAD POINT EXPANSION MODULE (PEM) HARDWIRE LOOPS RF EXPANSION MODULE (RFEM) RF RECEIVER M10907 Fig. 1. General overview of Honeywell System 7000. 69-1192—1...
  • Page 4 HONEYWELL 7000 SOLID STATE ALARM SYSTEM Location Mounting (Fig. 2 and 3) Locate the control panel enclosure in an area that is dry and Determine what equipment will be mounted on the wall with not subject to temperature extremes. Prolonged exposure to the control panel box, approximate location of each device, temperatures below 32°F (0°C) or above 120°F (50°C) can...
  • Page 5 HONEYWELL 7000 SOLID STATE ALARM SYSTEM BRICK, CONCRETE OR CINDER BLOCK WALL MOUNTING HARDWARE FOR PLYWOOD 3/4 IN. (19 MM) PLYWOOD CONTROL BOX M10909 Fig. 3. Mounting the control panel enclosure on plywood. Place the empty control panel box in the correct location on d.
  • Page 6 HONEYWELL 7000 SOLID STATE ALARM SYSTEM SYSTEM 7000 HOME CONTROL SYSTEM HOME AND BUILDING CONTROL MINNEAPOLIS, MINNESOTA HOUSEHOLD FIRE AND BURGLARY WARNING SYSTEM. U.L. HOME HEALTHCARE SIGNALING SYSTEM. HOUSEHOLD BURGLARY U.L. GRADE A WHEN USED WITH EXTERNAL AUDIBLE. WARNING: LEAVING THE POWER SWITCH...
  • Page 7 The PEM provides additional hardwire points for the screw locations on the wall or plywood. Use two screws (not Honeywell 7000 System and can be used in place of, or in supplied) to mount the PEM plastic box. Insert the PEM conjunction with, the RF transmitters and receivers.
  • Page 8 1. Use four-conductor AK4500A cable to connect the PEM The RFEM provides additional rf protection points for the to other HBus devices. Honeywell 7000 System. Only one RFEM can be used per 2. Connect the PEM wires to the control panel according system.
  • Page 9 HONEYWELL 7000 SOLID STATE ALARM SYSTEM MOUNTING SLOTS ON BACK OF RFEM DRYWALL OR PLYWOOD ANCHORS SUPPLIED RFEM (COVER REMOVED) M10911 Fig. 7. Installing the RFEM. 2. Place the open receiver on the wall in the desired RFEM Wiring location, leaving room for the two antennas.
  • Page 10: Keypad Wiring

    RF Receiver Wiring Keypad Wiring IMPORTANT Honeywell 7000 System keypads are connected to each No two receivers can have the same address other and to the control panel via the HBus. Follow these settings. Only address 1 or 2 can be used.
  • Page 11 HONEYWELL 7000 SOLID STATE ALARM SYSTEM WALL MOUNTING SCREWS (4) TOUCHPAD TRIM RING SCREW ANCHORS (4) MOUNTING BASE FOUR WIRES CONNECT TO HBUS M10604A SCREWS (4) Fig. 9. Standard surface mount of keypad. POWER SYSTEM 7000 SOURCE CONTROL KEYPAD KEYPAD...
  • Page 12 Fig. 13. Star HBus wiring. N.C. N.C. N.O. N.O. Hardwired Detection Circuits EOLR EOLR The Honeywell 7000 System control panel and each PEM 5.1K 1/4W 5.1K 1/4W has eight fully supervised hardwired input loops that can be NORMALLY OPEN CONTACTS NORMALLY CLOSED CONTACTS...
  • Page 13 4. Wire detectors as shown in Fig. 15. Two-Wire Smoke Detector Circuit The Honeywell 7000 System directly supports one two-wire fire circuit (loop 8 on the control panel). Use the following approved smoke detector models and refer Fire Marshals to the compatibility ID shown in Table 3.
  • Page 14 HONEYWELL 7000 SOLID STATE ALARM SYSTEM Four-Wire Smoke Detector Circuit Loop 8 of the Honeywell 7000 System control panel can supervise four-wire smoke detectors with the wiring arrangements shown in Fig. 19. Use the approved equipment listed in Table 4.
  • Page 15 HONEYWELL 7000 SOLID STATE ALARM SYSTEM RF Wireless Sensors Outputs The Honeywell 7000 System will work with a broad line of Honeywell 7000 System supports two solid state outputs on Series 5800 RF security and fire sensors when connected to the main control panel and two relay outputs on each PEM.
  • Page 16: Battery Installation

    Ademco 747UL Revere R44SSD The Honeywell 7000 System is powered by a 120 Vac to 24 Vac, 50A, plug-in transformer. Install the transformer as The following are general instructions for the bell or follows: horn installation. Follow the instructions specified for 1.
  • Page 17: Battery Calculations

    MINIATURE 8 POSITION PLUG M10906 TO REGISTERED TERMINAL EQUIPMENT Fig. 19. Simplified telephone company wiring diagram. Table 7. Current use of Honeywell 7000 System devices. Battery Calculations Normal Alarm Current The Honeywell 7000 System can have from one to Device...
  • Page 18 HONEYWELL 7000 SOLID STATE ALARM SYSTEM IMPORTANT This configuration requires one 7AH battery. The following limits must not be exceeded: Maximum normal total current: 1.05A. Maximum System Maximum alarm current on TB1-18 (HORN): 950 mA. The maximum system is any configuration that requires 28AH Maximum alarm current on TB1-17 (AUX): of standby battery power.
  • Page 19: Programming

    1. Power up the system. Make sure all keypad LED are off 1. Turn on the PC. and the keypad displays either FACTORY TEST or 2. Load and execute the System 7000 Programming MASTER ARM. program. 2. If the keypad displays FACTORY TEST, program the 3.
  • Page 20 35. Pick customer city. IMPORTANT 36. If necessary, pick time zone. Previous step should Do not program the Honeywell 7000 System to call a exclude need for this entry. fire or police station number unless authorized by 37. Set daylight savings parameters. See Programming that fire or police station.
  • Page 21: Operation

    This section provides general operation instructions for the Two LED’s between arrow keys. The LED next to the UP Honeywell 7000 Solid State Alarm System. All operating arrow, when lit, indicates that some Special Protection is procedures can be done from the keypad.
  • Page 22 “EXIT NOW” is displayed on line 1 of the Modes LCD. Audible Increases in speed for the last 10 seconds. Exit audible is silent for home occupancy 1. The System 7000 system allows you to manage modes. numerous security appliances with one control. In order 2. Burglary Alarm:...
  • Page 23 SPECIAL warning message on line 2. any other means, or 8. Transmitter In Trouble: 3. You want to turn off the System 7000 System for any The Transmitter In Trouble condition is due to the loss other reason. of the supervisory test message sent to the RF Receiver.
  • Page 24: Checkout

    NOTE: After performing this test and verifying that the any other means, or system is working properly, repeat the test with the 3. You want to turn off your System 7000 System for any customer/home-owner to show him how that the other reason.
  • Page 25: Troubleshooting

    Verify the control panel seizes the phone line and description is displayed. The only hardwire Fire point is dials out the police alarm and that the Honeywell 7000 P8. The KEYPAD will alarm locally, immediately and the does not send in a restore message to the CSC.
  • Page 26: Regulatory Agency Statements

    Honeywell should be contacted for service. least 4 minutes of File Alarm signaling. 5. The maximum Ampere Hour Battery load for System 7000 is 28 AG without a Listed Auxiliary Power Supply. 6. The minimum Ampere Hour Battery is 7 AH and current load is restricted to 210 milliamps normal standby and 1.185 amperes of alarm for 4 minutes for 24 hours of...
  • Page 27 If this equipment does cause interference to radio or television This equipment uses a RJ31X to connect the System 7000 to reception, which can be determined by turning the equipment the telephone network.
  • Page 28 HONEYWELL 7000 SOLID STATE ALARM SYSTEM Home and Building Control Home and Building Control Honeywell Asia Pacific Inc. Honeywell Inc. Honeywell Limited-Honeywell Limitée Room 3213-3225 Honeywell Plaza 155 Gordon Baker Road Sun Hung Kai Centre P.O. Box 524 North York, Ontario No.