LYNX Touch Installation and Setup Guide
Programming the Control
Note: If applicable, preprogrammed defaults for the LYNX Touch Control are shown on the screen unless otherwise noted.
SCREEN
System Settings
Entry Delay 1
30 Seconds
Entry Delay 2
60 Seconds
Exit Delay
60 Seconds
Backlight Timeout
No
Quick Arm
Yes
Select "System Settings"
The System displays the following options:
Entry Delay 1
Exit Delay
Quick Arm
Force Bypass
Use the down
arrow to scroll to the next page of options. Use the
the previous page:
Lack of Usage Notify
Display Alarm Cancel
Cross Zone Delay
Cross Zone 1
Select "Entry Delay 1". The System scrolls between the following options:
LYNX Touch
LYNX Touch SIA
None
30 Seconds
15 Seconds
45 Seconds
30 Seconds
60 Seconds
45 Seconds
90 Seconds
60 Seconds
2 Minutes
90 Seconds
3 Minutes
2 Minutes
4 Minutes
UL installations: The Entry Delay must be set for a maximum of 45 seconds
SIA: The Entry delay must be set to a minimum of 30 seconds. The sum of entry delay 1 and
the burglary abort window should not exceed 1 minute.
Select "Entry Delay 2". The System scrolls between the following options:
LYNX Touch
LYNX Touch SIA
None
30 Seconds
15 Seconds
45 Seconds
30 Seconds
60 Seconds
45 Seconds
90 Seconds
60 Seconds
2 Minutes
90 Seconds
3 Minutes
2 Minutes
4 Minutes
UL installations: The Entry Delay must be set for a maximum of 45 seconds
SIA: The Entry delay must be set to a minimum of 30 seconds. The sum of entry delay 2 and
the burglary abort window should not exceed 1 minute. The LYNX Touch SIA default is
"60 Seconds".
Select "Exit Delay". The System toggles between the following options:
LYNX Touch
LYNX Touch SIA
None
45 Seconds
15 Seconds
60 Seconds
30 Seconds
90 Seconds
45 Seconds
2 Minutes
60 Seconds
90 Seconds
2 Minutes
UL installations: Exit Delay must be set for a maximum of 60 seconds
SIA: The Exit Delay must be set to a minimum of 45 seconds.
Select "Backlight Timeout". The System toggles between No and 30 Seconds.
Select "Quick Arm". The System toggles between Yes and No.
WWW.DIYALARMFORUM.COM
ACTION
Entry Delay 2
Backlight Timeout
Quick Exit
Restart Exit Time
Exit Warning
Auto Stay Arming
Power-Up In Previous
Display Exit Time
Cross Zone 2