HR150, 200; ER150, 200 Perfect
Window™ Fresh Air Ventilation
Systems

APPLICATION

The HR150B and HR200B Perfect Window™ Fresh Air
Ventilation Systems provide proper levels of ventilation with
energy savings by transferring heat between the exhaust and
fresh air streams.
The ER150B and ER200B Perfect Window™ Fresh Air
Ventilation Systems provide proper levels of ventilation with
energy savings by transferring heat and moisture between the
exhaust and fresh air streams.
The ER150C and ER200C Perfect Window™ Fresh Air
Ventilation Systems are specifically designed for installations
in unconditioned spaces such as attics and garages in regions
where the outdoor temperature does not drop below freezing.

FEATURES

• Low voltage, high-speed override.
• Integral balancing dampers for quick installation.
• Provides ventilation that helps contractors meet
ASHRAE 62.
• 4-speed fan control.
• Automatic, economical built-in frost control available
for operation to design temperatures of -40°F (-40°C).
• HR150 and HR200 models have an easy-to-clean
aluminum cross-flow core.
• ER150 and ER200 models have an advanced enthalpy
heat and moisture recovery fixed core.
• Includes vibration isolation hardware and duct collars.
• Insulated cabinet made of rugged steel.
• Permanent (washable) prefilters.
• Quiet operation.
• Digital fan timer option on all models.
• Advanced ventilation algoritms available on
VisionPRO IAQ, TrueIAQ and W8150 controls.
• Interlock the ERV/HRV to an air handler or furnace
blower.
Application ........................................................................
Features ...........................................................................
Specifications ...................................................................
Ordering Information ........................................................
Planning the Installation ...................................................
Installation ........................................................................
Wiring ...............................................................................
Startup and Checkout ....................................................... 10
Service ............................................................................. 10
Troubleshooting ................................................................ 11
Parts List .......................................................................... 13
PRODUCT DATA
Contents
1
1
2
2
3
7
8
68-0171-10

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Perfect Window HR150

  • Page 1: Table Of Contents

    • 4-speed fan control. • Automatic, economical built-in frost control available for operation to design temperatures of -40°F (-40°C). • HR150 and HR200 models have an easy-to-clean aluminum cross-flow core. • ER150 and ER200 models have an advanced enthalpy heat and moisture recovery fixed core.
  • Page 2: Specifications

    If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2. Honeywell Customer Care...
  • Page 3: Planning The Installation

    HR150, 200; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS HIGH SPEED HIGH SPEED MEDIUM LOW SPEED MEDIUM LOW SPEED LOW SPEED LOW SPEED STATIC PRESSURE (IN W.G.) STATIC PRESSURE (IN W.G.) MANUFACTURER’S DATA MANUFACTURER’S DATA HR200/ER200 VENTILATION PERFORMANCE (HVI)
  • Page 4 HR150, 200; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS Example: 50 cfm intermittent • 3 bathrooms = 150 cfm FRESH AIR FROM OUTSIDE 20 cfm continuous • 3 bathrooms = 60 cfm — 100 cfm intermittent or 25 cfm continuous capacity for...
  • Page 5 HR150, 200; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS NOTES: — Do not locate the fresh air vent where it blows SEAL OUTER LINING OF FLEX directly onto occupants or the thermostat. DUCT TO OUTER COLLAR — Do not locate the fresh air intake close to known sources of pollutants such as automobile exhaust, a dryer vent or chimney smoke.
  • Page 6 HR150, 200; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS RETURN 40 IN. (1m) MINIMUM OUTDOORS NOTES: FORCED AIR FURNACE BLOWER IS REQUIRED TO OPERATE WHEN VENTILATION IS REQUIRED. FURNACE SET THE FURNACE BLOWER TO RUN CONTINUOUSLY, OR INTERLINK ELECTRICALLY (LOW VOLTAGE).
  • Page 7: Installation

    HR150, 200; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS Balancing Airflow INSTALLATION Balancing the airflow verifies that the Fresh Air Ventilation System is delivering the intended airflow and energy When Installing this Product… performance. Use the Airflow Balancing instructions in the Installation section to check and balance the airflow.
  • Page 8: Wiring

    HR150, 200; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS WIRING 3. Place the ventilator on the frame. Secure the ventilator to the frame using screws and a strip of wood or metal; screw into the side walls of the ventilator within 1 in. of the bottom.
  • Page 9: Fan Timer

    HR150, 200; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS SPEED CONTROL SWITCH LEGEND HIGH VOLTAGE LOW VOLTAGE BROWN YELLOW FIELD INSTALLED 12V LOW VOLTAGE AUTO TRANSFORMER BLACK 120V MOTOR SUPPLY CARD WHITE GROUND FAN MOTOR DETAILS T5 T6 GROUND...
  • Page 10: Startup And Checkout

    HR150, 200; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS Airflow Balancing STARTUP AND CHECKOUT Volume-balanced airflow in the ventilator is required. Volume of outside air brought in must equal the volume of air the unit After installation is complete, check to be sure system is exhausts.
  • Page 11: Troubleshooting

    HR150, 200; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS TROUBLESHOOTING See Table 1. Table 1. Troubleshooting Guide. Symptom Cause Solution Poor • Plugged outside hood 1/4 in. (6 mm) mesh. • Clean exterior hoods or vents airflow • Filters plugged.
  • Page 12 HR150, 200; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS Table 1. Troubleshooting Guide. Symptom Cause Solution Condensation • Incomplete vapor barrier around insulated duct. • Tape and seal all joints. or ice buildup • Tape any hole or tears made in outer duct covering.
  • Page 13: Parts List

    HR150, 200; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS PARTS LIST HR/ER Parts List Part Number for Item Number HR150B/ ER150B/ ER150C/ (Fig. 13) HR200B ER200B ER200C Description 209746 Heat Transfer Core, Aluminum with Plastic Frame 32002074-001 32002074-001 Cross-Flow Enthalpy Core, with Guide Channels, diamond...
  • Page 14 HR150, 200; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS M29738 Fig. 13. HR150/HR200 and ER150/ER200 exploded view of parts keyed to HR/ER Parts List. 68-0171—10...
  • Page 15 HR150, 200; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS 68-0171—10...
  • Page 16 HR150, 200; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive ® U.S. Registered Trademark Toronto, Ontario M1V 4Z9 © 2009 Honeywell International Inc.

Table of Contents