Honeywell Perfect Window HR150 Product Data

Fresh air ventilation systems
Hide thumbs Also See for Perfect Window HR150:

Advertisement

APPLICATION
The HR150, HR200, and HR205 Perfect Window™ Fresh Air
Ventilation Systems provide proper levels of ventilation with
energy savings by transferring heat between the exhaust and
fresh air streams.
The ER150 and ER200 Perfect Window™ Fresh Air
Ventilation Systems provide proper levels of ventilation with
energy savings by transferring heat and moisture between the
exhaust and fresh air streams.
The ER150C and ER200C are specifically designed for
installations in unconditioned spaces such as attics and
garages.
® U.S. Registered Trademark
Copyright © 2004 Honeywell International Inc.
All Rights Reserved
HR150, 200, 205; ER150, 200
Fresh Air Ventilation Systems
FEATURES
• Low voltage, high-speed override.
• Integral balancing dampers for quick installation.
• Provides ventilation that helps contractors meet
• 4-speed fan control.
• Automatic, economical built-in frost control available
• HR150, HR200 and HR205 models have an easy-to-
• ER150 and ER200 models have an advanced enthalpy
• Includes vibration isolation hardware and duct collars.
• Insulated cabinet made of rugged steel.
• Permanent (washable) prefilters.
• Quiet operation.
• Digital fan timer option on all models.
Application/Features..........................................................1
Specifications/Ordering Information ..................................2
Planning the Installation ....................................................5
Installation .........................................................................8
Wiring ................................................................................9
Startup and Checkout/Service ...........................................11
Troubleshooting.................................................................13
Parts List ...........................................................................15
Perfect Window™
ASHRAE 62-89.
for operation to design temperatures of -40°F (-40°C).
clean aluminum cross-flow core.
heat and moisture recovery fixed core.
PRODUCT DATA
Contents
68-0171-9

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Perfect Window HR150

  • Page 1: Table Of Contents

    • 4-speed fan control. • Automatic, economical built-in frost control available for operation to design temperatures of -40°F (-40°C). • HR150, HR200 and HR205 models have an easy-to- clean aluminum cross-flow core. • ER150 and ER200 models have an advanced enthalpy heat and moisture recovery fixed core.
  • Page 2: Specifications/Ordering Information

    If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2. Honeywell Customer Care...
  • Page 3 HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS cfm (L/s = n x 0.4719) cfm (L/s = n x 0.4719) GROSS SUPPLY GROSS EXHAUST NET SUPPLY NET EXHAUST HR200/ER200 VENTILATION PERFORMANCE (HVI) HR150/ER150 VENTILATION PERFORMANCE EXT STATIC...
  • Page 4 HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS FRESH AIR FROM OUTSIDE DEFROST STALE AIR PORT TO OUTSIDE (483) STALE AIR FRESH AIR FROM HOUSE TO HOUSE Fresh Air Ventilation System Système de ventilation à air frais...
  • Page 5: Planning The Installation

    HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS PLANNING THE INSTALLATION Option 2: Fresh Air Ventilation System provides continuous 93 cfm fresh air supply, 150 cfm intermittent exhaust capacity for bathrooms and continuous 50 cfm kitchen ventilation.
  • Page 6 HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS Keep intake and exhaust duct runs as short as possible with costs. When choosing this method, balance the ventilator few bends or elbows. when the air handler is running and interlock the ventilator •...
  • Page 7 HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS RETURN 40 IN. (1m) MINIMUM OUTDOORS NOTES: FORCED AIR FURNACE BLOWER IS REQUIRED TO OPERATE WHEN VENTILATION IS REQUIRED. FURNACE SET THE FURNACE BLOWER TO RUN CONTINUOUSLY, OR INTERLINK ELECTRICALLY (LOW VOLTAGE) USING OPTIONAL 32003248-001 BLOWER INTERFACE KIT.
  • Page 8: Installation

    HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS INSTALLATION Balancing Airflow Balancing the airflow verifies that the Fresh Air Ventilation System is delivering the intended airflow and energy When Installing this Product… performance. Use the Airflow Balancing instructions in the Installation section to check and balance the airflow.
  • Page 9: Wiring

    HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS WIRING 4. Connect the drain lines to a drain; see Installing Drain Line and P-Trap section. 5. Connect the ventilator to the ducts. CAUTION Installing Drain Line and P-Trap Electrical Shock Hazard.
  • Page 10 HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS SPEED CONTROL SWITCH LEGEND HIGH VOLTAGE LOW VOLTAGE BROWN YELLOW AUTO TRANSFORMER BLACK 120V MOTOR SUPPLY CARD WHITE GROUND FAN MOTOR DETAILS T5 T6 GROUND DEFROST GREEN DETAILS W8150A1001...
  • Page 11: Startup And Checkout/Service

    HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS Airflow Balancing Volume-balanced airflow in the ventilator is required. Volume of outside air brought in must equal the volume of air the unit exhausts. If airflow is not correctly balanced: •...
  • Page 12 HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS Inspecting Exterior Hoods IMPORTANT Blocked hoods can cause house/building pressure Inspect exterior hoods at least monthly. Be sure exhaust and change that can lead to possible combustion product fresh air supply hoods are not blocked or restricted by leaves, spillage from heating appliances.
  • Page 13: Troubleshooting

    HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS TROUBLESHOOTING See Table 1. Table 1. Troubleshooting Guide. Symptom Cause Solution Poor • Plugged outside hood 1/4 in. (6 mm) mesh. • Clean exterior hoods or vents airflow •...
  • Page 14 HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS Table 1. Troubleshooting Guide. Symptom Cause Solution Condensation • Incomplete vapor barrier around insulated duct. • Tape and seal all joints. or ice buildup • Tape any hole or tears made in outer duct covering.
  • Page 15: Parts List

    HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS PARTS LIST HR Parts List Part Number for Item Number (Fig. 13 and 14) HR150B HR200B HR205B Description 209746 209746 209746 Heat Transfer Core, Aluminum with Plastic Frame 208359...
  • Page 16 HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS ER Parts List Part Number for Item Number See Fig. 15 ER150 ER200 Description 32002074-001 32002074-001 Cross-Flow Enthalpy Core, with Guide Channels 208359 208359 Blower Motor 50002341-001 50002341-001 Blower Housing Kit...
  • Page 17 HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS Accessory Items Parts List Not Shown—All Models Item Number Part Number Description 208378 Ducting Elbow, 4 in., plastic 208373 Diffuser—4 in. diameter 208374 Diffuser—5 in. diameter 208375 Diffuser—6 in. diameter...
  • Page 18 HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS M15511C Fig. 13. HR150 and HR200 exploded view of parts keyed to HR Parts List. 68-0171-9...
  • Page 19 HR150, 200, 205; ER150, 200 PERFECT WINDOW™ FRESH AIR VENTILATION SYSTEMS M15476A Fig. 14. HR205 exploded view of parts keyed to HR Parts List. 68-0171-9...
  • Page 20 M11889B Fig. 15. ER150 and ER200 exploded view of ER Parts List. Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 Printed in U.S.A. on recycled 68-0171-9 G.H.