Sensor

______________________________________________________________________________________________
Document 800-06801 Rev B
06/10
Sensor Setup
1.
Use the arrow buttons to select Sensor 1 and press ENTER to
change to N/O (Normally Open) or N/C (Normally Closed).
2.
Repeat for all sensors.
3.
Select SAVE and press ENTER to save settings.
Alarm Setup
1.
Use the arrow buttons to select Alarm1 and press ENTER to turn the
SIGNAL to OFF or ON.
2.
Set each Alarm to N/O (Normally Open) or N/C (Normally Closed).
3.
Repeat for all relays.
4.
Select SAVE and press ENTER to save settings.
Power Off
The POWER OFF option is a preset function that triggers an alarm relay
when the DVR loses power. This function is preconfigured to set alarm
relay No. 4 to ON and N/C. When a power loss occurs, alarm relay No. 4
will open. When power is restored the alarm will close.
Note
SET and CLEAR are used to test the alarm relay operation. SET
is used to manually activate all relays that are set to ON.
CLEAR is used to manually deactivate all relays.
Performance Series DVR User Guide