Operation Of The Digital Operator; Names Of Parts - Hitachi J300 Series Instruction Manual

J300 series
Hide thumbs Also See for J300 Series:
Table of Contents

Advertisement

7. OPERATION OF THE DIGITAL OPERATOR

The standard type digital operator is modified so as to be used easily by minimizing key opera-
tions. Data can be set simply.
7.1

Names of Parts

FUNC (Function) key
This key is used for changing
commands. When pressing
key after setting data and
parameter, they are automati-
cally memorized.
The STOP/RESET key works only when a function is set. Prepare an emergency switch separately.
l
The use of the STOP/RESET key as an emergency switch may cause an injury.
7.2
Operation Procedure
(Example that the frequency is set and the equipment starts running)
Display after
power is turned
on
.
(Frequency
Press the
monitor)
key once.
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Monitor (LED display)
This display shows frequency, motor
current, motor revolution speed, and
Trip history
RUN key
This key is used for starting. (When
terminal run is selected, this key does
not work.)
FUNC
Press the
Press the
key five times.
key once.
FUNC
When selecting the monitor
mode, press
to display
FUNC.
FUNC.
FUNC.
FUNC.
FUNC.
STOP/
STOP/
RUN
RUN
STOP/
STOP/
STOP/
RUN
RUN
RUN
RESET
RESET
RESET
RESET
RESET
STOP/RESET key
This key is used for stopping the motor or
resetting errors.
(When either operator or terminal is se-
lected, this key works. If the extension
function is used, this function is void.)
WARNING
1
Start
run
Press
RUN
and
1
2
.
7-1
POWER Lamp
Power lamp of control
circuit
Up key, Down key
These keys are used to
change data and increase
or decrease the frequency.
FUNC
Press the
key once
and set the frequency by using
the
and
keys.
1
2
The frequency which is
set by the
stored.
.
key is
FUNC