Wiring Equipment, Options (Emi Filter, Etc.) - Hitachi J300 Series Instruction Manual

J300 series
Hide thumbs Also See for J300 Series:
Table of Contents

Advertisement

5.4

Wiring Equipment, Options (EMI filter, etc.)

Standard equipment
Power supply
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
(200V class)
Inverter
model
J300-055LF
J300-075LF
ELB
J300-110LF
J300-150LF
J300-220LF
Magnetic
contactor
J300-300LF
J300-370LF
J300-450LF
J300-550LF
(400V class)
Inverter
model
J300-055HF
J300-075HF
J300-110HF
J300-150HF
J300-220HF
J300-300HF
J300-370HF
J300-450HF
J300-550HF
J300-750HF
J300-900HF
J300-1100HF
J300-1320HF
J300-1600HF
J300-2200HF
Wiring (AWG or Kcmil)
Constant torqe
Variable torqe
Power
Power
Motor
Motor
lines
lines
output
output
R,S,T,U,V
R,S,T,U,V
(kW)
(kW)
W,P,N
W,P,N
AWG 8
AWG 8
7.5
5.5
or more
or more
AWG 6
AWG 6
11
7.5
or more
or more
AWG 4
AWG 4
15
11
or more
or more
AWG 3
AWG 3
22
15
or more
or more
AWG 1/0
AWG 1/0
30
22
or more
or more
AWG 3/0
AWG 3/0
37
30
or more
or more
AWG 4/0
AWG 4/0
45
37
or more
or more
300
300
55
45
or more
or more
350
350
75
55
or more
or more
Wiring
Constant torqe
Variable torqe
Power
Power
Motor
Motor
lines
lines
output
output
R,S,T,U,V
R,S,T,U,V
(kW)
(kW)
W,P,N
W,P,N
AWG 8
AWG 8
7.5
5.5
or more
or more
AWG 8
AWG 8
11
7.5
or more
or more
AWG 8
AWG 8
15
11
or more
or more
AWG 6
AWG 6
22
15
or more
or more
AWG 4
AWG 4
30
22
or more
or more
AWG 4
AWG 4
37
30
or more
or more
AWG 2
AWG 2
45
37
or more
or more
AWG 1
AWG 1
55
45
or more
or more
AWG 3/0
AWG 3/0
75
55
or more
or more
300
300
90
75
or more
or more
300
300
110
90
or more
or more
350
350
132
110
or more
or more
AWG 4 / 0
AWG 4 / 0
160
132
parallel
parallel
300
300
220
160
parallel
parallel
350
350
260
220
parallel
parallel
5-8
Applicable equipment
Power
Signal
Signal
Earth leakage
lines
lines
lines
breaker (ELB)
External
FM,CM1,PCL P24,AL0,AL1
resistor
FW,8,7,6,5,4,3 AL2
2,1,H,O,OL,L,
RB1,2,3,
CM2,12,11
P,RB
10
AWG 18
AWG 16
EX50C(30A)
or more
Shielded
or more
wire
10
EX50C(30A)
or more
EX50C(50A)
When the
number of
shielded
EX60B(60A)
wires to be
used is 11
RX100(75A)
or more,
the section
of each
RX100(100A)
shielded
wire
should be
RX100(100A)
AWG 20
RX225(150A)
RX225(175A)
Applicable equipment
Power
Signal
Signal
Earth leakage
lines
lines
lines
breaker (ELB)
External
FM,CM1,PCL P24,AL0,AL1
resistor
FW,8,7,6,5,4,3 AL2
2,1,H,O,OL,L,
RB1,2,3,
CM2,12,11
P,RB
10
AWG 18
AWG 16
EX50C(30A)
or more
Shielded
or more
wire
10
EX50C(30A)
or more
EX50C(50A)
When the
number of
shielded
EX60B(60A)
wires to be
used is 11
RX100(75A)
or more,
the section
of each
RX100(100A)
shielded
wire
should be
RX100(100A)
AWG 20.
RX225(150A)
RX225(175A)
RX225(225A)
RX225(250A)
RX400(350A)
RX400(400A)
RX600(600A)
RX600(600A)
Electro-
magnetic
contactor
H20
H20
H25
H35
H50
H65
H80
H100
H125
Electro-
magnetic
contactor
H20
H20
H25
H35
H50
H65
H80
H100
H125
H150
H220
H250
H400
H600
H600

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents