Low Power Time-Out Timer
Scan the Low Power Time-Out barcode to change the time-out duration (in sec-
onds). Then scan the time-out duration (from 0-300 seconds) from the inside
back cover, and Save . Default = 120 seconds.
If the unit remains idle during the low power time-out interval, the unit goes into
low power mode. Whenever the trigger is enabled, the low power time-out timer
is reset.
Note: This time-out does not begin until the imager time-out setting has expired.

In-Stand Sensor Mode (4600r only)

The 4600r (Software revision 31205480-118 or higher) contains a sensor that
senses when the imager is removed from the stand (HFSTAND5RSE only).
Refer to the
Show Software Revision
ing the software in your unit. The imager then enters Manual Trigger mode. If
you wish to turn the sensor on, scan the Sensor ON barcode below. Default =
Off.
Sensor On

Scan Stand Mode

Note: Scan Stand Mode is only available for non-advanced illumination units
with software revision 31205480-090 or lower. Refer to the
Software Revision
software in your unit.
Low Power Time-Out
on page 11-2 for information on determin-
on page 11-2 for information on determining the
* Sensor Off