receiver time-out by scanning the barcode below, then scanning digits from the
inside back cover of this manual, then scanning Save . The range is 0 to 300
seconds. Default = 0 seconds (no time-out - always on).

RS-232 Handshaking

RS-232 Handshaking allows control of data transmission from the Imager using
software commands from the host device. When this feature is turned Off , no
data flow control is used. When Data Flow Control is turned On , the host
device suspends transmission by sending the XOFF character (DC3, hex 13) to
the Imager. To resume transmission, the host sends the XON character (DC1,
hex 11). Data transmission continues where it left off when XOFF was sent.
Default = RTS/CTS, XON/XOFF and ACK/NAK Off .
RTS/CTS On
XON/XOFF On
ACK/NAK On

Wand Emulation Connection

The Wand Emulation Connection barcodes should be used if you want to
change the terminal ID only , without changing any other imager settings. We
recommend using Wand Emulation Plug & Play barcodes to program your
imager to emulate a wand reader. The Wand Emulation Plug & Play barcodes
change other parameters, in addition to changing the terminal ID. Please refer
to
Connecting the Imager with RS-232 Wedge
tion.
2 - 12
RS-232 Receiver Time-Out
* RTS/CTS Off
* XON/OFF Off
* ACK/NAK Off
on page 1-6 for further informa-