GE ZET1 Installation Instructions Manual page 4

30" {76.2 cm) built-ln wall oven
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
Allow 11/16"
(1.75 cm) for
overlapof
oven over
side edges
of cutout
Cutout for Single
Cutout Width
28 1/2" Min.
7 3/4"
(]
n}
28 518" Max.
J_{72.4
to 72.7
Opening
Between
Inside
Walls
Must
Be At Least
28 1/2"
(72.4 cm}
Wide
21"
(53.3
......
Allow1"(2.5 cm}
.......
minimum for
overlap
of oven
Allow a minimum
top and 1¼"
of 21" (53.3 cm} for
I
{3.2 cm} overlap
clearance to adjacent
L
of oven bottom of
corners, drawers, wails,
L_
cutout
etc. when
_
_'_
Cabinet
door
is open
"
_
Width
30" {76.2 cmL
27 1/4" Min.
27 5/16" Max.
{69.2 to 69.4 cm
uilt-ln Oven
Junction
Box Location
{junction
box
may be located
in
adjacent
cabinet}
Recommended
cutout
location
from
floor
32
112" {82.6 cm}
22" {55.9 cm}
Min. to Bottom
of Junction
Box
Cabinet Width
Recommended
Cutout
Location
from Floor
Cutout Depth
Cutout Width
Cutout Height
30" (76.2 cm)
32 112"(82.6 cm)
23 1/2"(59.7 cm) Min.
28 1/2"{72.4 cm) Min.
28 5/8"(72.7 cm) Max.
27 1/4"(69.2 cm) Min.
27 5/16"(69.4 cm) Max.
NOTE: If the cabinet
does
not have a front
frame
and the
sides are less than
3/4" (1.9 cm)
thick,
shim both
sides equally
to
establish
the cutout
width.
If the cabinet
does not have a solid
bottom,
two
braces
or runners
must
be installed
level with
the bottom
of the cutout
to support
the weight
of the oven.
For single
ovens,
the runners
and
braces
must
support
200 Ibs. 190 kgl.
NOTE: If marks,
blemishes
or the cutout
opening
are visible
above
the installed
oven,
it may be necessary
to add wood
shims
under
the runners
and front
trim
until
the marks
or opening
are covered.
Side by Side Installations
InstGII two wall ovens in separate
cutouts.
Allow 2" (5.1 cm) min. between
cutouts.
Cutout
-
Observe all
dimensions
and
requirements.
2" (5.1 cm)
Min.
Cutout
-
Observe
all
dimensions
and
requirements.
Suitable
Bracing
to Support
Runners
Install a
solid bottom
or 2" x 4"
{5 cm x 10 cm} or
equivalent
runners
level with bottom
of cutout
21 5/8"
I
{54.9 cm)
Over Centerline
/
of Cabinet
The solid bottom or runners must be level with
the bottom of the cutout,
or the bottom trim
may not install correctly
and then interfere
with the door opening.
This oven is not approved
for stackable
installation,
4