Direct air convection built-in electric wall oven, 30" single wall oven (40 pages)
Summary of Contents for GE ZET1
Page 1
Installation 30" Built-In Wall Oven Instructions ZET1,ZET2 If you have questions, call 1.800.GE.CARES or visit our website at: ge.com Before You Begin • Proper installation is the responsibility of the installer and product failure Read these instructions carefully and completely.
Installation Instructions IMPORTANT SAFETY INSTRUCTIONS For Your Safety This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly grounded branch • Be sure your oven is installed properly circuit, protected by a circuit breaker or fuse a qualified installer or service technician.
Installation Instructions Pre-lnstallation Checklist Open oven door and remove ALL INSTALLATION INFORMATION literature pack, broiler pan and grid, ON THE FOLLOWING PAGES IS TO oven racks, rack supports and a bag BE USED FOR SINGLE AND DOUBLE with 9 hex nuts. OVEN INSTALLATION! Read Installation Instructions carefully before you begin.
Page 4
Installation Instructions Pre-lnstallation Checklist cont To Remove the Door (if necessary) Place the oven on a table or platform Door removal is not a requirement Ilk _1_ even with the cutout opening. installation of the product, but is an added convenience. To remove the door: (Platform must support...
Installation Instructions Cutout for Single Built-In Oven Under Counter Gas or electric cooktops may be installed over this oven, See cooktop installation instructions for cutout size. See label on top of oven for Gas and electrical connections approved cooktop models. 30"...
Page 8
Cabinetry Single Oven Cutout Double Oven Cutout for Installation Over for Installation Over a Monogram Warming a Monogram Warming Drawer 231,2, Drawer 231,2,, (59.7 cm) (59.7 cm) _Min. i_,__Min, Inside--* 2" x 2" (5 cm x 5 cm) or 2" x 2"...
Page 9
Cabinetry Single Oven Cutout Single Oven Cutout for Installation Below for Installation Between a Monogram Advantium a Monogram Advantium Oven 231,2- Oven and a Monogram (59.7 cm) Warming Drawer Min. ns de_ 23 1/2" i_(s9.7 cm) Inside Per Advantium Requiremer Per Advantium Min.
Installation Instructions Electrical Connections Turn off the circuit breaker or remove ATTENTION INSTALLER fuses to the oven branch circuit. All electric wall ovens must be hard wired With the oven supported on a table (direct wired) into an approved junction or platform in front of the cabinet box.
Page 11
Installation Instructions IBI Electrical Connections cont. New Construction This oven is supplied with a 48" (123 cm) long flexible conduit consisting of: Four-Conductor Branch 3 insulated conductors (copper) Circuit Connection 1 bare ground conductor (copper) • When installing in new construction, or r-B--_ Attach conductors to residence wiring as shown by wiring diagram.
Page 12
Installation Instructions lcl Securing the Oven in the Opening Sliding the Oven Into Drilling the Pilot Holes the Opening and Mounting the Oven a. Loop (do not tie) a 36" (91 cm) string NOTE: Before drilling the pilot holes, around the conduit before the oven is slid make sure the oven is pushed as far into place.
Page 13
Installation Instructions Installing the Oven Installing the Metal Bottom Trim Rack Supports and Oven Racks a. Place the bottom trim between the side trim and against the bottom of the cutout. Oven Rack Supports b. Using two trim screws provided, secure Place the rack support with the slotted the bottom trim to the bottom edge of the...
Page 14
Installation Instructions I-D-1 Replacing the Oven Door Open the oven door as far as it NOTE: The oven door is heavy. You will open. may need help lifting the door high enough to slide it into the hinge slots. Push the hinge locks up against the Do not lift the door by the handle.
Installation Instructions Pre-Test Checklist Check that the bottom trim is installed emove all protective film, if present, and any stickers. properly (see page 13). Check to be sure that all wiring is secure Check to be sure the mounting screws are and not pinched or in contact with moving installed and flush with the side trim (see parts.