Exhaust Information - GE 49-90383 Installation Instructions Manual

Table of Contents

Advertisement

Installation
Instructions
CONNECTING
APPLIANCE USING
4-WIRE CONNECTION
F1"1 Remove the terminal block access cover.
r-8
Install UL-listed 30A, 4-conductor NEMA 1/4-30-
type STclosed loop terminal power cord and the
strain relief.
Connect the green ground wire of the power
cord to the terminal block bracket with the green
grounding screw.
Connect the white wire from the power cord
and the green ground wire from the appliance
harness to the center (silver-colored) terminal
of the terminal block.
Connect the black and red wires from the power
cord to the two outer terminals of the terminal
block.
Greenconductor Silver terminal
Terminalblock
groundscrew
(14-30R)
4-wire receptacle
_D
groundwire
Blackwire
Redwire
wire
I_-I
Check all connection screws to make sure they
are securely tightened.
FT-I
Reinstall the terminal block access cover.
6
CONNECTING
APPLIANCE USING
4-WIRE CONNECTION
(CONT.)
A CAUTION: Be
sure electricity is OFFat power
source (circuit breaker/fuse box).
F8-1
Plug power cord into electrical outlet.
I_
Return to Step 15 on page 3.
NOTE:TH ISAPPLIANCEISNOTAPPROVEDFOR120-VOLT
OPERATION.
EXHAUST INFORMATION
WARNING - To reduce the risk offire
or personal
injury:
• This clothes dryer must be exhausted to the outdoors.
• Use only 4" rigid metal ducting for the home exhaust
duct.
• Use only 4" rigid metal or UL-listed flexible metal
(semi-rigid or foil-type) duct to connect the dryer to
the home exhaust duct. It must be installed in
accordance with the instructions found in "Connecting
the Dryer to House Vent" on page 7 of this manual.
• Do not terminate exhaust in a chimney, a wall,
a ceiling, gas vent, crawl space, attic, under an
enclosed floor, or in any other concealed space
of a building.
• Never terminate the exhaust into a common duct
with a kitchen exhaust system. A combination
of grease and lint creates a potential fire hazard.
• Do not use duct longer than specified in the exhaust
length table. Longer ducts can accumulate lint,
creating a potential fire hazard.
• Never install a screen in or over the exhaust duct.
This will cause lint to accumulate, creating a potential
fire hazard.
• Do not assemble ductwork with any fasteners that
extend into the duct. These fasteners can accumulate
lint, creating a potential fire hazard.
• Do not obstruct incoming or exhausted air.
• Provide an access for inspection and cleaning of the
exhaust system, especially at turns and joints. Exhaust
system shall be inspected and cleaned at least once
a year.
• Remove and discard existing plastic or metal foil duct
and replace with UL-listed duct.
• Remove any lint from the wall exhaust opening.
Internal_
Wall
duct
opening __}:_t-'-
Check thatexhaust
__
.... [I
hooddamper opens
"_
_
andcloses freely.