Download Print this page

GE Spacemaker WSM2700 Installation Instructions Manual

Electric laundry
Hide thumbs Also See for Spacemaker WSM2700:

Advertisement

A
A&
WARNING-
POTENTIAL
FIRE AND SHOCK HAZARD
• Use only rigid metal or flexible metal 4" diameter ductwork inside the dryer cabinet or for exhausting
to the outside. Use of plastic or other combustible
ductwork can cause a fire. Foil or other easily
punctured ductwork can cause a fire if it collapses or becomes restricted
in use or during installation.
• This appliance must be properly grounded and installed as described in these instructions.
Important
Exhausting
the dryer to the outside is strongly
recommended
to prevent large amounts
of moisture
.
and lint from being blown into the room.
Service information
and wiring diagram located in dryer
access panel.
Tools Required
Slip joint pliers
Phillips
head and flat blade screwdrivers
Ratchet
with 3/8" socket
Carpenter's
level
Contents:
PROCEDURE
-
Page 2
-
Page 4
ELECTRICAL
-
Page 5
-
Page 6
-
Page 7
ALCOVE & CLOSET
-
Page 8
-
Page 8
-
Page 8
Product
Dimensions
,
0
®
VENT
75 1,'2"
_-_-
WATER INLETS
(REAR)
54 5/16"
DRAIN
OUTLET
7
['_ - 3 314"
27"----
*
25 1/4"
-_
*_'- 2 1/2"
11 7116"

Advertisement

loading

Summary of Contents for GE Spacemaker WSM2700

  • Page 1: Table Of Contents

    A& WARNING- POTENTIAL FIRE AND SHOCK HAZARD • Use only rigid metal or flexible metal 4" diameter ductwork inside the dryer cabinet or for exhausting to the outside. Use of plastic or other combustible ductwork can cause a fire. Foil or other easily punctured ductwork can cause a fire if it collapses or becomes restricted in use or during installation.
  • Page 2 Installation INSTALLATION (Cont.) NOTE: The tub blocking pad, shipping bolt and Unpacking Spacemaker _ plastic spacer should be retained for use if the STEP 1 - Remove tape and two comer pads from rear appliance is transported at a later date. bottom comers of appliance.
  • Page 3 INSTALLATION (cont.) INSTALLATION (cont.) STEP 13 - Determine which water faucet is the HOT MovingSpacemaker to OperatingLocation: water faucet and carefully connect the bottom inlet STEP 10 - Remove the two screws securing hose to the HOT water faucet, tighten by hand, then access panel to the dryer cabinet.
  • Page 4: Installation

    Drain Requirements INSTALLATION (cont.) DRAIN RATE - The drain or standpipe must be Appliance Operational Checkout: capable of accepting a discharge at the rate of !6 STEP 17 - All packing and shipping materials gallons per minute, removed including the washer shipping bolt and DRAIN HEIGHT...
  • Page 5 Connecting ApplianceUsing3-Wire Connection ELECTRICAL (cont,) STEP 1 - Remove the terminal block cover located at 3-Wire Connection (Ungrounded Neutral) the rear of the dryer. This appliance is manufactured with the neutral connected to the frame. If local codes do not permit neutral grounding, proceed as follows:...
  • Page 6: Exhaust Information

    ELECTRICAL ELECTRICAL (cont.) (cont.) GREEN GROUND SILVERTERMINAL SCREW GREEN Connecting ApplianceUsing4-Wire Connection CONDUCTOR _1_30R) 4*WIRE RECEPTACLE GROUND GREEN WIRE STEP 14 - Remove the terminal block access cover. STEP 14E - Check all connection screws for being securely tightened. STEP 14F - Re-install the terminal block cover.
  • Page 7: Mobile Home Installation

    EXHAUST (cont.) EXHAUST (cont.) ExhaustDuctLengthInformation Sealing of Joints The MAXIMUM ALLOWABLE length of the All joints should be tight to avoid leaks. exhaust system depends upon the type of duct, NOTE: The male end of each section of duct must number of turns, the type of exhaust hood (wall...
  • Page 8: Installation

    Alcoveor ClosetInstallation Door VentilationOpening A minimum of 120 square inches of opening, equally divided at top and bottom is required. Air opeffmgs are i.,- o. required to be unobstructed when a door is installed. louvered door with equivalent air openings for the full SQ IN length of door is acceptable.